18
We Think of Customer Satisfactio
n
F. 1
(Maximum Discharge Time)
① SOLENOID Maximum operating time adjustment function.
② 3rd, 4th digits: 20 seconds (5 seconds ~ 30 seconds, Set Unit of one second).
F. 2
(Complete removal of ice in the reservoir)
① This function can be entered in "OFF" state of ICE MAKING-OFF-WASH switch.
② Press two buttons (WATER, ICE) simultaneously for 3 seconds and Button part LED lights up.
③ Press the discharge lever for continuous operation of SOLENOID and the motor.
Keep 'ON' state.
F. 3
(Automatic ice discharge function)
① When ICE, WATER & ICE button is selected, ice is automatically emitted for the set time.
② Automatic operation is not possible when OFF is set. (Manual operation)
③ Automatic discharge is performed for the set time of At01 ~ 99.
F. 4
(Initial water subtraction function)
① It operates first when "ICE MAKING" switch is operated.
② FND 1st, 2nd digits (drain time) 30 seconds (oF ~ 99 seconds, Set Unit of one second)
③ Water supply operation after drainage to high water level.
④ FND 3rd, 4th digits (number of repetitions) Standard: 3 times (1 ~ 9 times)
F. 5
(Automatic drain function)
① It operates when "ICE MAKING" switch is operated.
② FND 1st, 2nd digits (drain time): 2 seconds (oF ~ 9 seconds, Set Unit of one second)
③ FND 3rd, 4th digits (drain interval): 1.0 hour (0.5 ~ 9.5 hours, every 30 minutes)
F. 6
(ICE + WATER volume control)
① 1st, 2nd digits Ice time Default 5 seconds (up to 99 seconds)
② 3rd, 4th digits Water time Default 5 seconds (up to 99 seconds)
F. 7
(UV LAMP time adjustment)
① 1st, 2nd digit lighting time Default 3 minutes (99 minutes possible)
② 3rd, 4th digits off time Default 1 hour (9 hours available)
F. 8
(Notify service period setting)
① A.1.0 After using 10,000 hours, the corresponding mode LED blinks for 5 seconds (for the first 5 seconds during ice making)
② A.1.1 After using 11,000 hours, all LEDs blink for 5 seconds (1 hour cycle)
F. 9
(Cumulative uptime)
① The FND display is displayed in year, month, day, and hour, and is displayed in order from right to left.
② Cumulative operation time of product is expressed in hour unit.
③ Calculation example: 12 months for 1 year, 30 days for 1 month, 24 hours for 1 day.
F. 10
(Change temperature unit)
Function of setting the unit of temperature in degrees Celsius or Fahrenheit
F. 11 F. 12 F. 13
Evaporation inlet temperature display Evaporation outlet temperature display Choose ice and water discharge method
ordE : Discharge ice first and then discharge water
join : Simultaneous discharge of ice and water
Function Button Description (FND Display Window)
※ Setting value reset function
- Pressing three buttons of UP,
DOWN, and SET for 3 seconds
at the same time will set all
setting values to default values
Содержание ID-0160-AN
Страница 25: ...25 8 Circuit Diagram...
Страница 29: ...29 MEMO...
Страница 30: ...30 We Think of Customer Satisfaction MEMO...
Страница 31: ...31 MEMO...
Страница 32: ...3240453 20 Online Internet Service http www icetro com...