fAULT
cAUse
reMeDY
The machine
does not start.
TroUbLe sHooTiNg /2
“ Dry ice Pellets evaporate immediately
on striking the object. ”
The machine is
turned on but it
does not blast.
no supply of electricity.
the emergency stop is activated
(pressed inwards).
the blasting gun has not been
activated.
no supply of compressed air.
no electrical connection between
the gun and the blasting hose
and/or between the blasting
hose and the machine.
loose connections, defective plugs,
damaged cables.
The
flow
of
air and dry ice is
blocked
because the blasting hose is kinked
or
extremely
inflexed.
“motor failure”
“motor overload”
“Valve overload”
check that the battery is fully charged
and correctly connected.
for more information: see page 13.
release the emergency button
(pull outwards and make
sure it can turn).
activate the blasting gun.
check the machine is properly
connected to a source of compres-
sed air and that the air actually
flows
into
the
machine.
The air
hose
must be
inflated
and
rigid, and that the pressure must
be
verified
in the
manometer
on
the front panel.
make sure the electrical plug of the
gun is correctly attached to the
electrical socket of the blasting
hose, and make sure the plug at
the other end of the blasting hose
is correctly plugged into the socket
on the front of the machine.
check all connectors, cables, replace
defective parts or correct loose
connections.
straighten up the blasting hose.
the motor needs replacement
– call for a service engineer.
press the emergency stop button.
pull it out again after 5 seconds.