Installation

Installation of ceramic

Connect the Angle-valve at the Shut-off valve.

Insert the flange-packing into the flange.

flange-packing 

flange

Turn the ceramic over. Place the flange at the bottom of ceramic and insert 

the bolts assemble the flange and ceramic with packing nuts.

Lift up the ceramic and fix the flange at a drain.

Set the ceramic at level not to lean when

fixing the flange.

• Ceramic is heavy. 

   Recommend 2 workers when lifting up the ceramic.

flange

Drain

Bolts

Wax seal

Flange

or

11

10

IMPORTANT NOTE: 

Please  read  through  this  entire  list  of  instructions  and  take  an  inventory  of  included 

parts before beginning installation. If you have any questions at all, please call Customer 

Service at 855-444-2372 before you begin your installation.

INSTALLATION STEPS

• 

The centerline of the floor drain is to be 12” from finished back wall. Do not 

include the thickness of any base board molding when taking this measurement.

• 

The centerline of the angle stop (wall valve) is to be 8” above the finished floor 

and 6” to the left of the centerline of the floor drain. The angle stop will need 

to have a 1/2” MIP thread to connect to the included supply line.

Before unpacking product, ensure that rough-in dimensions are as follows:

VERY IMPORTANT:  Follow instructions in order! Connect hoses 

and attach seat top to bowl BEFORE putting the down the bowl.

1a. 

 Screw the 1/2” supply line (included) to the angle stop. Hand tighten only. 

1b. 

Open the angle stop and allow water to flow into the floor drain for 60 seconds. DO NOT 

SKIP THIS STEP! Construction debris in the pipes will clog the unit’s filter. This applies to new 

construction as well. Turn off valve and remove supply line when complete.

1a

1b

Содержание S-20 RF

Страница 1: ...and use Please save this instruc on manual and place in an easily accessible loca on External appearance and specifica ons are subject to change for improvement of product without no ce Muse iWash CS...

Страница 2: ...persons including children with reduced physical sensory or mental capabilities unless under the supervision of a responsible adult Use this product only for its intended use as described in this man...

Страница 3: ...wer cord and call Icera Customer Service for assistance Using a malfunctioning seat may be a fire and or electric shock hazard Do not dismantle repair or alter the unit unless under the instruction of...

Страница 4: ...n Main unit 3 Seat Control Panel Floor Bolt Covers Non sittable Seat Lid Manual Flush Buttons Deodorizer Vent Rear Wash Spray Warm Air Dryer Outlet Front Wash Spray In bowl LED Nightlight Seat Sensor...

Страница 5: ...4 Parts Identification Light sensor Control Panel Remote control Top Front 04...

Страница 6: ...removed to expose 1 2 MIP threads x1 GFCI receptacle x1 wired in wall and tested Bowl to flange gasket x1 a waxless ring is recommended although a bee s wax ring may be used Pair of 2 1 2 long toilet...

Страница 7: ...ill cease and the nozzle will return to its res ng positon You can supplement by wiping gently with toilet paper if desired When si ng on the seat sit in the center to ensure the seat sensor detects t...

Страница 8: ...adjust the water pressure it will default to the last used se ng Nozzle Posi on Adjustment Water Pressure Adjustment Press on the remote to adjust the temperature of the warm air If you choose not to...

Страница 9: ...flush automa cally when it detects a user has vacated the seat a er si ng for 5 seconds or more In the event of a power outage the Auto Flush will not operate See below for instruc ons on how to flush...

Страница 10: ...G USER PRESETS Quickly press and release the user preset desired to ac vate A short beep will sound when the user preset is ac vated STANDARD In Standard mode the seat temperature will be maintained a...

Страница 11: ...your installation INSTALLATION STEPS The centerline of the floor drain is to be 12 from finished back wall Do not includethethicknessofanybaseboardmoldingwhentakingthismeasurement The centerline of th...

Страница 12: ...Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 11 3 Unbox the bowl Viewing from the back you ll notice 2 factory installed braided stainless steel lines One...

Страница 13: ...the ceramic flange Drain Bolts Wax seal Flange or 11 12 4a Unbox the bidet seat and the rest of the bowl Hand tighten the bowl jet supply line to the 1 2 plastic inlet on the left bottomside of the s...

Страница 14: ...the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 13 5a Install seat anchors included in bowl deck holes 5b Insert plastic hold down...

Страница 15: ...is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 14 6a Hand tighten 1 2 brass adapter to the water filter both included 6b Hand tighten filter to 3 4...

Страница 16: ...lean when fixing the flange Ceramic is heavy Recommend 2 workers when lifting up the ceramic flange Drain Bolts Wax seal Flange or 11 15 8 GENTLY align bowl over drain flange guiding mounting bolts th...

Страница 17: ...e Drain Bolts Wax seal Flange or 11 16 10 Hand tighten 1 2 supply hose to angle stop Use a wrench to tighten fully Ensure supply hose is not kinked or awkwardly bent The hose should appear as in the p...

Страница 18: ...gain a er about 5 minutes The warm air dryer is not warm Is the DRY temperature set at low Adjust the temperature se ng to a higher level AUTO FLUSH does not operate Is there power to the outlet Use M...

Страница 19: ...he flush is complete Make sure the plug is securely connected Unplug the unit and plug another device into the outlet to make sure there is power Check points Check the followings details before calli...

Страница 20: ...p Adjustment Water Pressure Adjustment Front Wash Rear Wash Direct connec on to the water supply Thermal Fuse Thermostat Thermal Fuse Thermal Fuse Bi metal Water Flow Rate AmbientTemperatureRange Seat...

Страница 21: ...channel in homes where two or more units are installed in close proximity If two units are being ac vated by a single remote follow the steps below to adjust the frequency on one remote 1 Turn the uni...

Страница 22: ...sure adjustment bu on again The LED light should move on the remote which indicates the change to the next channel You can select any of the frequency channels shown below except for Channel 1 which i...

Страница 23: ...ective product or installation costs of replacement pieces Excluded from coverage through this warranty are items used as plumbing fixture trim various fittings toilet bowl seats and tank flushing mec...

Страница 24: ...hanges in finish scratching staining and other effects from chemical use water and atmospheric conditions are not considered manufacturing defects but are considered normal wear and tear Variations in...

Страница 25: ...Warranty ICERA USA P O Box 4238 Westminster CA 92684 P 855 444 2372 E service icerausa com 6522 0482 00 Rev 0...

Отзывы: