32
OPERATOR MANUAL
/ / -OB /
Check Proximity
Sw
Release Handle
Turn Dead SW Off
RE-START
Replace Control
Unit
Replace Control
Unit
Check Detergent
Pump
Check Detergent
Pump
Communication
Error
Main Relay Short
Circuit
Main Relay Open
Circuit
Main Relay Short
Circuit
Main Relay Open
Circuit
Drive Motor Short
Circuit
Check the proximity
switch
Release the control
handle ball
Release emergency
stop button and restart
the machine
Contact Service Center,
Replace the Control
Unit
Contact Service Center,
Replace the Control
Unit
Check Detergent Pump
Check Detergent Pump
Replace Panel or Re-
place controller unit
Check lead wire and
connector
Check lead wire and
connector
Check lead wire and
connector
Check lead wire and
connector
Check propel motor/
wiring
Proximity
switch fault
Operation
mistake
Emergency stop
button activated
Bad Control
Unit
Bad Control
Unit
Detergent Pump
Short Circuit
Detergent Pump
Short Circuit
Check control
unit and panel
connector
Main Relay (#1)
Short Circuit
Main Relay (#1)
Open Circuit
Main Relay (#2)
Short Circuit
Main Relay (#2)
Open Circuit
Drive Motor
Short Circuit
F40
F41
F43
F49
F50
F53
F54
F60
F61
F62
F63
F64
F65
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
FAULT
CODE
FAULT
MESSAGE
FAULT
CAUSE
SOLUTION
Model
Содержание 20NBL+-OB
Страница 1: ...i20NBL i20NBL OB i20NBTL i24BTL Auto Scrubber Operator Manual ...
Страница 2: ......
Страница 39: ...39 OPERATOR MANUAL i20NBL i20NBTL i20NBTL OB i24BTL ...
Страница 40: ...40 CE APPROVAL i20NBL i20NBTL i20NBTL OB i24BTL ...
Страница 41: ...41 CE APPROVAL i20NBL i20NBTL i20NBTL OB i24BTL ...