Page 22

Page 22

2.

Unloose the three screws securing the plastic

cover to the gear motor speed sensor housing
and remove it.

3.

Unloose the two screws securing the sensor

to the plastic housing and withdraw it from its
seat.

4.

Trace the gear motor speed sensor terminal

plug (red with four pins) on the left side of the
control box and draw it out from its socket by
carefully slackening the fastening tie.

5.

To install the replacement gear motor rotation

and speed sensor follow the above steps in
reverse.

F.

REPLACEMENT OF THE RESERVOIR
WATER LEVEL SENSOR

1.

Remove the front and top panels.

2.

Unloose the two nuts securing the wire leads

to the two water level sensor rods located on the
water reservoir plastic cover.

3.

Trace the water level sensor terminal plug

(red) on the left side of the control box and draw
it out from its socket by carefully slackening the
fastening tie.

4.

To install the replacement water level sensor

follow the above steps in reverse.

G.

REPLACEMENT OF P.C. BOARD

1.

Remove front panel.

2.

Remove all sensor terminal plugs, located

on the left side of P.C. Board, by carefully releasing
them out from their sockets clips.

3.

Disconnect the terminal board connection

plug from the rear side of P.C. BOARD then
unloose the four screws holding the same to the
plastic control box and remove it.

4.

To install the replacement P.C. BOARD follow

the above steps on reverse.

NOTE. In case the TEST contacts are jumped
together (it is a possibility when PC Board is
replace as spare parts), the machine starts
up immediately with all the electrical parts
(compressor, drive motor and fan motor start
together with no delay).
This for 3 minutes then the machine stops
with all LEDs blinking.

H.

REPLACEMENT OF THE ICE SPOUT

1.

Remove the top panel.

2.

Slacken and remove the two metal straps

that hold tight the polystyre insulations against
the freezer upper part.

3.

Remove the optical ice level control.

4.

Unloose and remove the two screws and the

spout  from the freezer cylinder.

5.

To install the replacement spout follow

previous steps in reverse.

I.

REPLACEMENT OF THE AUGER, WATER
SEAL, BEARINGS AND COUPLING

1.

Remove the front, side and top panels.

2.

Follow the steps at item H to remove the ice

spout.

3.

Grasp the wire cap hook at the top of the

freezer and pull out the auger and attached cap,
ice breaker, bearings and O rings, at the top of
the auger, and the top half of the water seal at the
auger bottom.

NOTE. If the auger cannot be pulled out,
proceed to steps 9 and 10 of this paragraph,
to gain access to the auger bottom. Then,
with a rowhide mallet or placing a piece of
wood on the bottom end of the auger, tap this
bottom to break loose the auger and be able
then to pull it out as in step 3 above.

4.

With a circlip plier remove the retaining ring

and cap hook from the ice breaker.

5.

Unloose and remove cap screw and remove

the ice breaker from the auger.

6.

Clean away the old grease from the interior

of the ice breaker and inspect the conditions of
the O ring; if torn or worn replace it.

7.

Inspect the bearing pressed into the top of

the ice breaker and if worn do not hesitate to
replace it.

WARNING. The top bearing assembly works
in critical conditions for what concern its
lubrication status as it is haused in the ice
breaker where the formation of a great
rate of condensation is usual. Therefore it
is important to apply on it an ample coa-
ting  of  Food  grade  Waterproof  Grease
P/N 263612.00 before installing the breaker
and cap hook in place.

0.5-1.0 mm

Содержание ICEF 155

Страница 1: ...Page 1 Page 1 SERVICE MANUAL ICE UNDERCOUNTER SERIES CUBER MODEL ICEF 155 Rev 07 2014...

Страница 2: ...rain connections Final check list Installation practice OPERATING INSTRUCTIONS Start up Operational checks PRINCIPLE OF OPERATION How it works Water circuit Refrigerant circuit Mechanical system Opera...

Страница 3: ...ak performance levels periodic maintenance checks must be carried out as indicated on page 29 of this manual Important operating requirements MIN MAX Air temperature 10 C 50 F 40 C 100 F Water tempera...

Страница 4: ...NS Model Cond unit Finish Comp HP Ice bin cap Water req lt 24 HR ICEF 155 MACHINE SPECIFICATIONS Dimensions HEIGHT less legs 794 mm HEIGHT with legs 929 mm WIDTH 529 mm DEPTH 621 mm WEIGHT 51 Kg 230 5...

Страница 5: ...nting pads 8 Use clean damp cloth to wipe the surfaces inside the storage bin and the outside of the cabinet 9 See data plate on the rear side of the unit and check that local main voltage corresponds...

Страница 6: ...ter or conditioner WATERSUPPLY WATERCOOLEDMODELS The water cooled versions of Ice Makers require two separate inlet water supplies one for the water making the flaker ice and the other for the water c...

Страница 7: ...Have the bin liner and cabinet been wiped clean 10 Has the owner user been given the User Manualandbeeninstructedontheimportanceof periodic maintenance checks G INSTALLATION PRACTICE 1 Hand shut off v...

Страница 8: ...hardastheevaporating temperature has not yet reached the correct operating value It is necessary to allow the ice just made to cure itself and wait for about ten minutes for the evaporating tem peratu...

Страница 9: ...SER TEMP EVAPORATOR TEMP ICE LEVEL CONTROL TRANSF T 40 50 C DATA PROCESSOR L N 11 10 9 1 2 7 8 6 5 4 3 13 12 FIG 3 2 1 L N COMPRESSOR 9 10 11 12 13 3 4 5 6 7 8 CONTACTOR COIL GEAR MOTOR FAN MOTOR ELEC...

Страница 10: ...PERATION CHECKS UPON THE UNIT START UP D Removefrontservicepanelandifnecessary install the refrigerant service gauges on the corresponding Service valves to check both the HI and LO refrigerant pressu...

Страница 11: ...of the flaker operations and the glowing of the YELLOW LED of shortage of water even though that water is indeed in the reservoir After this open the water supply line shutoff valve to fill up again t...

Страница 12: ...ss of the two optical eyes are covered by a thin lay of scale To do it just follow the following procedure With unit OFF push and old the Reset Button of the PC Board Give power to the machine through...

Страница 13: ...the ice level raises to interrupt the light beam running between the two infrared Leds the unit stops after six seconds with the simulteneous glowingofthe YELLOWLEDsignallingthe Full Bin situation NO...

Страница 14: ...unit trips OFF again in alarm for 3 times in 3 hours the machine SHUTS OFF DEFINITIVELY After having eliminated the source of the excessive con densertemperature torestarttheicemachine it is necessary...

Страница 15: ...4 5 6 7 8 CONTACTOR COIL GEAR MOTOR FAN MOTOR ELECTRONIC CARD RELAYS TRIAC RESET S E N S O R S WATER LEVEL GEAR MOTOR ROTATION CONDENSER TEMP EVAPORATOR TEMP ICE LEVEL CONTROL TRANSF DATA PROCESSOR L...

Страница 16: ...em always check the type of refrigerant and quantity as specified on the individual ice machine dataplate Therefrigerantchargesindicatedarerelatives to averages operating conditions OPERATING PRESSURE...

Страница 17: ...tage to the P C BOARD In case the condenser temperature sensor detects a temperature at the condenser lower than 1 C 33 F that signify that the ambient temperature is at the same value therefore it is...

Страница 18: ...LED F P C BOARD Data processor The P C BOARD fitted in its plastic box located in the front of the unit consists of two separated printed circuits one at high and the other at low voltage and protecte...

Страница 19: ...low to maintain a constant water level in the reservoir level that corresponds to the one in thefreezingcylindertoensurepropericeformation and fluidity On the inner side of the reservoir cover are fit...

Страница 20: ...erefrigerant vaporcausingitstemperaturetoriseandbecome high pressure hot vapor which is then released through the discharge valve NOTE Itisveryimportanttomakesureofthe correct fitting of the cover on...

Страница 21: ...ezertotheaccumulator to gain access to the sensor probe well and be able to pull out from this well the sensor probe 3 Trace the condenser sensor terminal plug blue on the left side of the control box...

Страница 22: ...he machine stops with all LEDs blinking H REPLACEMENT OF THE ICE SPOUT 1 Remove the top panel 2 Slacken and remove the two metal straps that hold tight the polystyre insulations against the freezer up...

Страница 23: ...e off from the auger bottom the upper half of the water seal NOTE Any time the auger is removed for replacement or inspection use extra care in handling the water seal parts so no dirt or foreignmatte...

Страница 24: ...It is imperative to install a replace ment drier whenever the sealed refrigeration system is open Do not replace the drier until all other repairs or replacements have been completed 8 To install the...

Страница 25: ...Page 25 Page 25 WIRING DIAGRAM AIR AND WATER COOLED 230 50 60 1...

Страница 26: ...Page 26 Page 26...

Страница 27: ...freezer for scores Replace whatever worn or damaged No rotation of gear motor Check for power to drive motor 16 A fuses Check for stator winding Gear motor starts and stop Check for correct operation...

Страница 28: ...leaking Tighten screws holding the spout Excessive noise or chattering Mineral or scale deposit on auger Remove and manually polish auger and inner freezer walls and inner walls of freezer barrel usin...

Страница 29: ...t temperature sensor 8 Check for water leaks and tighten drain line connections Pour water down bin drain line to be sure that drain line is open and clear 9 Check the ice level control sensor to test...

Страница 30: ...heoverflow NOTE The ice made with the cleaning solution is slushy and coloured also it may tendtoloosefluiditycreatingsomeresistence in being elevated and extruded this situation canbeheardbythecreack...