Page 18

Page 18

the light source and the sensor gets interrupted
by the flake ice which accumulates in the spout.
When the light beam is interrupted the Bin Full
YELLOW LED
 located in the front of the P.C.
BOARD blinks; in case the light beam gets
interrupted for as long as 6 seconds, the ice
machine stops with the glowing-up of the 2nd
YELLOW LED
 to monitor the full ice bin situation.
The 6 seconds of delay prevents that any
minimum interruption of the light beam due to the
regular ice chuting through the ice spout may
stop the operation of the unit.

NOTE. During the life of the machine the Ice
Level Control may require a recalibration
mainly when the glass of the two optical eyes
are covered by a thin lay of scale.
To do it just follow the following procedure:
• With unit OFF push and old the Reset

Button of the PC Board

•  Give power to the machine through the

Green Master Switch

• Hold the PC Board Reset Button till the

leds start to blink/flash (more or less 10
seconds)

• Release the PC Board Reset Button
The Optical Ice Level Control is now
recalibrated.
Check for the correct operation of the Optical
Ice Level Control by plasing a handfull of ice
in between the two eyes.
The Bin Full yellow led must start to blink/
flash immediately and, 10 seconds later, the
machine must trip OFF.

As soon as the ice is scooped out (with the
resumption of the light beam between the two
infrared sensor of ice level control) 10 seconds
later the ice machine resumes its operation with
the simul-taneous extinguishing the 2nd YELLOW
LED.

F.

P.C. BOARD (Data processor)

The P.C. BOARD, fitted in its plastic box located
in the front of the unit, consists of two separated
printed circuits one at high and the other at low
voltage and protected by fuses. Also it consists of
five aligned LEDS monitoring the operation of the
machine of three jumpers (TEST used only in the
factory, 60/70

°

C used to set up the PC Board at

proper safety cut out condensing temperature
and 3' to by pass the 3 minutes Stand By) and of
input terminals for the leads of the sensor probes
as well as input and output terminals for the leads
of the ice maker electrical wires.
The P.C. BOARD is the brain of the system and
it elaborates, through its micro processor, the
signals received from the sensors in order to
control the operation of the different electrical
components of the ice maker (compressor, gear
motor, etc.).

The five LEDS, placed in a row in the front of the
P.C. BOARD, monitor the following situations:

GREEN LED
Unit under electrical
power

YELLOW LED
- Blinking:

I/R beam cut
out

- Steady:

unit shut-off at
storage bin full

- Blinking fast: I/R beam resumed

YELLOW LED

Unit shut-off due to a
too lo-water level into
float tank

RED LED

ON all the time
- Unit shut-off due to a too

hi-condensing temperature

- Unit shut-off due to a

too lo-ambient temperature
<+1

°

C

Blinking
3 minutes start up delay time

YELLOW LED

ON all the time
- Unit shut-off due to the wrong

rotation direction of gear motor

- Unit shut-off due to the

too lo speed of gear motor

Blinking
- Unit shut-off due to a
 too hi-evaporating temp.
>-1

°

after 10 min of operation

YELLOW AND
RED LED

- Blinking: Evaporator sensor

out of order

- Steady:

Condenser sensor
out of order

- Blinking alternatively: Ice level

control out of order

Содержание ICEF 155

Страница 1: ...Page 1 Page 1 SERVICE MANUAL ICE UNDERCOUNTER SERIES CUBER MODEL ICEF 155 Rev 07 2014...

Страница 2: ...rain connections Final check list Installation practice OPERATING INSTRUCTIONS Start up Operational checks PRINCIPLE OF OPERATION How it works Water circuit Refrigerant circuit Mechanical system Opera...

Страница 3: ...ak performance levels periodic maintenance checks must be carried out as indicated on page 29 of this manual Important operating requirements MIN MAX Air temperature 10 C 50 F 40 C 100 F Water tempera...

Страница 4: ...NS Model Cond unit Finish Comp HP Ice bin cap Water req lt 24 HR ICEF 155 MACHINE SPECIFICATIONS Dimensions HEIGHT less legs 794 mm HEIGHT with legs 929 mm WIDTH 529 mm DEPTH 621 mm WEIGHT 51 Kg 230 5...

Страница 5: ...nting pads 8 Use clean damp cloth to wipe the surfaces inside the storage bin and the outside of the cabinet 9 See data plate on the rear side of the unit and check that local main voltage corresponds...

Страница 6: ...ter or conditioner WATERSUPPLY WATERCOOLEDMODELS The water cooled versions of Ice Makers require two separate inlet water supplies one for the water making the flaker ice and the other for the water c...

Страница 7: ...Have the bin liner and cabinet been wiped clean 10 Has the owner user been given the User Manualandbeeninstructedontheimportanceof periodic maintenance checks G INSTALLATION PRACTICE 1 Hand shut off v...

Страница 8: ...hardastheevaporating temperature has not yet reached the correct operating value It is necessary to allow the ice just made to cure itself and wait for about ten minutes for the evaporating tem peratu...

Страница 9: ...SER TEMP EVAPORATOR TEMP ICE LEVEL CONTROL TRANSF T 40 50 C DATA PROCESSOR L N 11 10 9 1 2 7 8 6 5 4 3 13 12 FIG 3 2 1 L N COMPRESSOR 9 10 11 12 13 3 4 5 6 7 8 CONTACTOR COIL GEAR MOTOR FAN MOTOR ELEC...

Страница 10: ...PERATION CHECKS UPON THE UNIT START UP D Removefrontservicepanelandifnecessary install the refrigerant service gauges on the corresponding Service valves to check both the HI and LO refrigerant pressu...

Страница 11: ...of the flaker operations and the glowing of the YELLOW LED of shortage of water even though that water is indeed in the reservoir After this open the water supply line shutoff valve to fill up again t...

Страница 12: ...ss of the two optical eyes are covered by a thin lay of scale To do it just follow the following procedure With unit OFF push and old the Reset Button of the PC Board Give power to the machine through...

Страница 13: ...the ice level raises to interrupt the light beam running between the two infrared Leds the unit stops after six seconds with the simulteneous glowingofthe YELLOWLEDsignallingthe Full Bin situation NO...

Страница 14: ...unit trips OFF again in alarm for 3 times in 3 hours the machine SHUTS OFF DEFINITIVELY After having eliminated the source of the excessive con densertemperature torestarttheicemachine it is necessary...

Страница 15: ...4 5 6 7 8 CONTACTOR COIL GEAR MOTOR FAN MOTOR ELECTRONIC CARD RELAYS TRIAC RESET S E N S O R S WATER LEVEL GEAR MOTOR ROTATION CONDENSER TEMP EVAPORATOR TEMP ICE LEVEL CONTROL TRANSF DATA PROCESSOR L...

Страница 16: ...em always check the type of refrigerant and quantity as specified on the individual ice machine dataplate Therefrigerantchargesindicatedarerelatives to averages operating conditions OPERATING PRESSURE...

Страница 17: ...tage to the P C BOARD In case the condenser temperature sensor detects a temperature at the condenser lower than 1 C 33 F that signify that the ambient temperature is at the same value therefore it is...

Страница 18: ...LED F P C BOARD Data processor The P C BOARD fitted in its plastic box located in the front of the unit consists of two separated printed circuits one at high and the other at low voltage and protecte...

Страница 19: ...low to maintain a constant water level in the reservoir level that corresponds to the one in thefreezingcylindertoensurepropericeformation and fluidity On the inner side of the reservoir cover are fit...

Страница 20: ...erefrigerant vaporcausingitstemperaturetoriseandbecome high pressure hot vapor which is then released through the discharge valve NOTE Itisveryimportanttomakesureofthe correct fitting of the cover on...

Страница 21: ...ezertotheaccumulator to gain access to the sensor probe well and be able to pull out from this well the sensor probe 3 Trace the condenser sensor terminal plug blue on the left side of the control box...

Страница 22: ...he machine stops with all LEDs blinking H REPLACEMENT OF THE ICE SPOUT 1 Remove the top panel 2 Slacken and remove the two metal straps that hold tight the polystyre insulations against the freezer up...

Страница 23: ...e off from the auger bottom the upper half of the water seal NOTE Any time the auger is removed for replacement or inspection use extra care in handling the water seal parts so no dirt or foreignmatte...

Страница 24: ...It is imperative to install a replace ment drier whenever the sealed refrigeration system is open Do not replace the drier until all other repairs or replacements have been completed 8 To install the...

Страница 25: ...Page 25 Page 25 WIRING DIAGRAM AIR AND WATER COOLED 230 50 60 1...

Страница 26: ...Page 26 Page 26...

Страница 27: ...freezer for scores Replace whatever worn or damaged No rotation of gear motor Check for power to drive motor 16 A fuses Check for stator winding Gear motor starts and stop Check for correct operation...

Страница 28: ...leaking Tighten screws holding the spout Excessive noise or chattering Mineral or scale deposit on auger Remove and manually polish auger and inner freezer walls and inner walls of freezer barrel usin...

Страница 29: ...t temperature sensor 8 Check for water leaks and tighten drain line connections Pour water down bin drain line to be sure that drain line is open and clear 9 Check the ice level control sensor to test...

Страница 30: ...heoverflow NOTE The ice made with the cleaning solution is slushy and coloured also it may tendtoloosefluiditycreatingsomeresistence in being elevated and extruded this situation canbeheardbythecreack...