ELEVATION SERIES CIM CUBER HIGH AND LOW FLOAT SWITCHES AND HOUSING
39
High and Low Float Switches and Housing
Float Housing Assembly
The Float Switch Housing Assembly contains the High and Low Float Switches along with the
Sump Thermistor. See below for function of each. See also Sequence of Operation pg. 9.
High and Low Float Switch Operation
The High Float Switch is used to control the water level for ice making, cleaning and sanitizing.
The Float will rise with the water level, opening the contact of the switch and signal the Board to
close the Water Inlet Valve. The LED associated with the High Float switch will be ON when the
contacts of the switch are closed, and will turn OFF when the contacts open. The Low Float
Switch is used to determine when the unit is ready to go into the Harvest Cycle during ice pro‐
duction and when the Sump has been emptied of cleaner or sanitizer during the Cleaning Cycle.
The LED associated with the Low Float Switch operates the same as the LED for the High Float
Switch. The LED will ILLUMINATE when the contact of the float are closed and will turn OFF
Switch Closed
Position
Switch Opens half
way up Stem.
Switch Closed
Position
High Float
Switch Function
Low Float
Switch Function
Switch Opens half
way up Stem.
High
Float
Low
Float
Thermistor
Содержание CIM Series
Страница 31: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 29 INITIAL HARVEST CYCLE AT START UP ...
Страница 32: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 30 TRANSITION FROM HARVEST TO FREEZE ...
Страница 33: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 31 BIN FULL CURTAIN OR STAT ...
Страница 35: ...ELEVATION SERIES CIM CUBERS BOARD COMPONENT LED SEQUENCE 33 DIAGNOSTICS IN HARVEST CYCLE ...
Страница 36: ...ELEVATION SERIES CIM CUBERS BUTTON FUNCTIONS 34 Button Functions ...
Страница 77: ...ELEVATION SERIES WIRING DIAGRAM 75 CIM220V 240V 50Hz SINGLE PHASE SINGLE EVAPORATOR REMOTE COOLED UINTS ...
Страница 78: ...ELEVATION SERIES WIRING DIAGRAM 76 CIM 230V 60Hz THREE PHASE SINGLE EVPAORATOR PLATE REMOTE COOLED UNITS ...
Страница 80: ...ELEVATION SERIES WIRING DIAGRAM 78 CIM 220V 240V 50Hz SINGLE PHASE DUAL EVAPORATOR AIR AND WATER COOLED UNITS ...
Страница 81: ...ELEVATION SERIES WIRING DIAGRAM 79 CIM 230V 60Hz THREE PHASE DUAL EVAPORATOR AIR AND WATER COOLED UNITS ...
Страница 82: ...ELEVATION SERIES WIRING DIAGRAM 80 CIM 115V and 230V 60Hz SINGLE PHASE DUAL EVAPORATOR REMOTE COOLED UNITS ...
Страница 83: ...ELEVATION SERIES WIRING DIAGRAM 81 CIM 220V 240V 50Hz SINGLE PHASE DUAL EVAPORATOR REMOTE COOLED UNITS ...
Страница 84: ...ELEVATION SERIES WIRING DIAGRAM 82 CIM 230V 60Hz THREE PHASE DUAL EVAPORATOR REMOTE COOLED UNITS ...