47
Autonomous Hard Floor Scrubber Cobi 18
User Manual
Battery & On Board Battery Charger
Cobi 18 has an on board Lithium Ion Battery and battery charger. Do not remove the battery or charger unless
authorized to do so.
Battery
Battery Charger
Nominal Voltage
25VDC
Nominal Capacity
25Ah
Allowed Max Charging Current
15A
Charging Temperature
0-45°C (32-113°F) /5~95%RH
Discharge Temperature
20-55°C (68-131°F) /5~95%RH
Storage Temperature
-10-30°C (14-86°F)
1. Only use the specific battery provided with Cobi 18. Do not
remove the battery unless authorized.
2. Battery power button must be turned on while machine is
charging or while machine is in use.
3. If machine is not being used for a long time, periodic charging
may be necessary.
4. Always keep the battery door open for ventilation when charging.
Input Voltage
100 -240 Vac 50/60 Hz
Output Voltage
24VDC
Charging Current
5A
Temperature & Humidity
0-40°C (32-104°F) /20~55%RH
LED : GREEN ON
Wait for Charging / Fully charged
LED : YELLOW FLASH
Charging in progress
LED : RED FLASH
Charging Error
1. Only use the specific battery charger that Cobi 18 was delivered
with. Do not remove the battery charger unless authorized to do
so.
2. Always keep the battery door open for ventilation when charging.
3. Connect the AC power cable to approved power supply. A clear
window to the right of the battery door will allow visibility to the
charging status. Yellow will flash when battery is charging.
4. When the LED turns to Green, the battery is fully charged,
unplug the AC power cord and store it on the back of battery
compartment door.
5. If the LED light is flashing red, there is a charging error. Please
ensure the power cord is plugged into an approved outlet and
the battery power button is "on".
6. Please contact ICE Cobotics customer service if issue continues
to exist.