Precautions and preparations listed are for general knowledge and to define basic guidelines. Local codes and existing practices should be observed and preformed by a professional. 

Due to ICE AIRs ongoing product development programs, the information in this document is subject to change without notice.

Room Temp Probe

L

N

Optional

WHT

V

WHT

RED

HTG
BRN

BLK
CLG

Auto Change Over

YEL

WHT

WHT

BRN

C

BRN

Fan

Motor

BLU

GRD

N

Circuit #1

To Low Voltage

Thermostat

Transformer

ELA-8693/ELA-8694

Relay Board

Notes:

1. Some components on legend are not 
    used on all schematics.
2. Cap off unused wire on fan motor 
    when present.

Component Outline

Field Wiring

Factory Wiring

Wire Color

Wire Connector

Field Connector

CLG

HTG

C

SI

V

Legend:

BLK

CAP

Front

  3 

1

  6 

4

  9 

7

 12  11  10

  1 

3

  4 

6

  7 

9

 10  11  12

Mount

Guide

Wiring

Guide

Back

COM

NO

RED

BLU

BLK

LOW

HI

MED

  1 

3

  4 

6

  7 

9

 10  11  12

P2
P1

CON1

R
C
COOL
F1
F2
F3
H1
H2
P
G
RT

F1
F2
F3
HEAT1
HEAT2

Cooling

Heating

Capacitor

3 Speed Switch

Valve

Wire Chart

1

BLK

Common

2

RED

24VAC

3

YEL

Cooling

4

WHT

Heat

5

— Not in Use —

6

GRN

Lo-Cool

7

BLU

Me-Cool

8

— Not in Use —

9

ORN

Hi-Cool

10

GRY

Room Temp

11

PUR

G

12

BRN

Pipe Sensor

2 Pipe System

General Electric

Line Voltage

Wiring, including the electrical ground, must comply with the National 
Electrical Code as well as all applicable local codes. Refer to the 
Electrical Data table for fuse sizes. Consult the wiring diagram below 
for field connections on the right of the electrical diagram located on 
the back of the unit electrical compartment front panel. All electrical 
connections must be made by the installing (or electrical) contractor. 
All final electrical connections must be made with a length of flexible 
conduit to minimize vibration and sound transmission to the building.

p

!

  

WARNING:

 Electrical shock can cause personal injury or death 

while installing or servicing the system. Always turn OFF the 
main power to system. There may be more than one  
disconnect switch.

General Line Voltage Wiring

Be sure the available power is the same voltage and phase shown 
on the unit serial number plate. Line and low voltage wiring must be 
done in accordance with local codes or the National Electric Code, 
whichever is applicable.

Power Connection

Units equipped with disconnect:

 Connect incoming line voltage 

to the disconnect switch and connect ground wire to the ground lug 
provided inside the electrical compartment.

Units without disconnect:

 Line voltage connection is made by 

connecting the incoming line voltage wires to the terminal block.

10

Содержание FCHC

Страница 1: ...codes and existing practices should be observed and preformed by a professional Due to ICE AIRs ongoing product development programs the information in this document is subject to change without notic...

Страница 2: ...ervice or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license t...

Страница 3: ...ctions Units should be installed no closer than 18 apart when two units are side by side A vertical clearance of 60 should be maintained between units 2 Adequate ceiling panel access must exist for ha...

Страница 4: ...l Elec Heat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Ite...

Страница 5: ...e Item 16 A Flow Regulation Cooling Coil A Balancing Valve B Circuit Setter C Autoflow Valve 0 5 GPM D Autoflow Valve 1 0 GPM E Autoflow Valve 1 3 GPM F Autoflow Valve 1 5 GPM G Autoflow Valve 2 0 GPM...

Страница 6: ...LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Item 6 X Enclosure X...

Страница 7: ...Way MV Normally Open Diverting 17 24V 3 Way MV Normally Closed Routing w Bypass Pipe 18 24V 3 Way MV Normally Closed Diverting w Bypass Pipe 19 24V 3 Way MV Normally Open Routing w Bypass Pipe 20 24V...

Страница 8: ...ithout interference 7 A minimum obstructed distance of 36 should be kept around theunit IMPORTANT To avoid permanent damage to the unit DO NOT operate during construction in an open space or as a supp...

Страница 9: ...n the unit Piping Installation ICE AIRs Horizontal Concealed Fan Coil is available in either 2 pipe or 4 pipe configurations see below that are connected to the system through the use of a flexible ho...

Страница 10: ...2 Pipe System General Electric Line Voltage Wiring including the electrical ground must comply with the National Electrical Code as well as all applicable local codes Refer to the Electrical Data tab...

Страница 11: ...n motor when present Component Outline Field Wiring Factory Wiring Wire Color Wire Connector Field Connector CLG HTG C SI V Legend BLK CAP Front 3 2 1 6 5 4 9 8 7 12 11 10 1 2 3 4 5 6 7 8 9 10 11 12 M...

Страница 12: ...system with water leaving the air vents open Bleed all air from the system but do not allow the system to over flow Check the system for leaks and make any required repairs 4 Adjust the water and air...

Страница 13: ...leshooting Table Troubleshooting IMPORTANT It is not the intent of this maintenance manual to resolve any problems with the operation of your ICE AIR unit Please contact a trained servicer or building...

Страница 14: ...ation in Building Date Sales Order No In order to minimize troubleshooting and costly system failures complete the following checks and data entries before the system is put into full operation Temper...

Страница 15: ...son including any agent salesman dealer or distributor has authority to expand ICE AIRs obligation beyond the terms of these express warranties or to state that the performance of the product is other...

Отзывы: