![ICC DNET-100 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/icc/dnet-100/dnet-100_user-manual_609876064.webp)
63
firmware to its flash memory: all other application functions (such as
communications, console access etc.) will be disabled.
15.3
Using the RFU Utility
Support for downloading new application firmware to the gateway is provided
by the free Rabbit Field Utility (RFU), which is a 32-bit application that runs on
Microsoft Windows platforms. The RFU utility can be downloaded from ICC’s
home page at
http://www.iccdesigns.com
. When downloading a new gateway
application BSP, always confirm that you also have the latest version of RFU,
as new .BIN firmware files contained in BSPs may require functionality found
only in the most recent RFU versions for successful downloading.
The remainder of this section will detail the RFU utility configuration and
firmware download procedures.
15.3.1
Required Files
When first downloaded, the RFU utility files are compressed into one self-
extracting .EXE distribution file. Create a folder (such as c:\RFU), place the
distribution file in this folder, and then execute it. This will extract the
compressed files. The distribution file is then unneeded and can be deleted if
desired. To run the RFU utility, double-click on the RFU.EXE file icon.
15.3.2
First-Time Configuration
The first time the RFU utility is run on a computer, several configuration items
need to be confirmed. These configuration items are retained in the
computer’s registry from that point on, so reconfiguration is not required unless
certain parameters (such as which serial port to use on the computer) are
changed.
The two configuration items that need to be confirmed are the communications
characteristics and bootstrap loaders path. First, select the
“Setup…Communications” menu item (refer to Figure 32).
Содержание DNET-100
Страница 8: ...7 2 Mechanical Diagrams 2 1 Enclosure Figure 2 Enclosure Dimensions units are inches ...
Страница 9: ...8 2 2 Mounting Clip Figure 3 Mounting Clip Dimensions units are inches ...
Страница 11: ...10 ASD Link LEDs Reserved LEDs ASD 2 ASD 3 ASD 1 Figure 6 Top View ...
Страница 38: ...37 Figure 13 HyperTerminal Configuration Screen 1 Figure 14 HyperTerminal Configuration Screen 2 ...
Страница 39: ...38 Figure 15 HyperTerminal Configuration Screen 3 ...
Страница 68: ...67 16 Notes ...
Страница 69: ...68 ...