iCanView222 User’s Guide
Do not apply power through this power input when Standard PoE connection is used.
y
ALARM IN/OUT and Composite Video Output: Used for connecting P/T device, sensor,
and alarm devices to iCanView222. Note that the bottom most pin is numbered as 1. Pin
assignments are as follows
Pin
Description
Misc.
1 SNS
IN
(+)
Sensor
In
(+). NC/NO selectable in
admin mode.
2
SNS In (-)
Sensor In (-). NC/NO selectable in
admin mode.
3
CVBS OUT(+)
Composite video output
4
CVBS OUT(-)
Ground for composite video output
5
RLY OUT
Relay output : closed circuit in alarm
to indicate alarm status
6 RLY
OUT
.
SNS IN :
Connect external alarm sensors such as the
infrared sensors, heat sensor,
magnetic sensors, etc. NC/NO selectable in the admin page.
RLY OUT :
It is used for connecting external alarm generators such as sirens,
flashing light, etc. When activated, relay output configures a closed circuit.
Please refer to Section 6.1 for more detailed description on the Alarm In/Out
connections.
y
Reset :
Factory Default Switch
There is a switch provided for returning the network camera to factory default state. Open the
dome cover to access the switch. Press the switch through a tiny hole using tools with sharp
tip for a few seconds while power is applied.
2.4. PC Requirements
AV streaming data received from iCanView222 can be decoded or stored in a PC running i-NVR
program which is a viewing & recording program for a PC. Minimum requirement of the PC is
described below:
Rev.1.0 (Mar. 2008)