IBS CPL350 Скачать руководство пользователя страница 4

 

 
Last update: 

2022-05-19 

 

www.ibspe.com 

User Manual |

 

P4

 

 

5

 

Using this manual 

In this manual you will find information for connecting and using your CPL350. Once you become familiar with the 
system, you will only need to refer occasionally to this manual for specifications or to verify connection 
information. 

 

6

 

Helpful Technical Support Documents Online 

The IBS Precision Engineering’s website has a large selection of technical documents (TechNotes and Application 

Notes) in the Technical Library. These documents provide detailed descriptions of the operation and use of the 
products of IBS Precision Engineering. 

The Technical Library can be accessed at: 

https://www.ibspe.com/expertise/technical-resources

  

Some of the titles include: 

 

Understanding Capacitive and Inductive Sensors 

 

Comparing Capacitive and Inductive Sensors 

 

Z-height Measurement with Non-contact Sensors 

 

Sensor Operation and Optimization 

 

Using Capacitive Sensors in Vacuum Applications 

 

Understanding Electrical Runout When Using an Eddy-Current Sensor for Roundness Measurements 

 

Inductive Probe Cabling Considerations 

 

 

 

Содержание CPL350

Страница 1: ...www ibspe com User Manual P1 CPL350...

Страница 2: ...TEM CONTENTS 3 4 CALIBRATION 3 5 USING THIS MANUAL 4 6 HELPFUL TECHNICAL SUPPORT DOCUMENTS ONLINE 4 7 CONNECTING TO THE CPL350 5 7 1 PROBE CONNECTIONS 5 7 2 ANALOG OUTPUT BNC CONNECTOR 5 7 3 POWER DIF...

Страница 3: ...or provides one channel of noncontact displacement measurement for precision position and displacement applications This manual will provide you with all the information you require to get the greates...

Страница 4: ...Notes and Application Notes in the Technical Library These documents provide detailed descriptions of the operation and use of the products of IBS Precision Engineering The Technical Library can be ac...

Страница 5: ...mes more positive as the probe gets closer to the target The scaling of the output i e V mm is dependent on the probe and calibration specified when ordered The complete calibration information is ava...

Страница 6: ...puts are each 5 VDC relative to ground the differential output is therefore 10 VDC CAUTION Do NOT connect the outputs to ground or the unit will be damaged Differential Outputs as Single Ended The Non...

Страница 7: ...PL350 is set to 15 kHz unless specified otherwise in the order and on the calibration sheet received with the system Two switches inside the enclosure set the bandwidth To change them Remove the 4 scr...

Страница 8: ...ion Bandwidth 3 dB DIP Switch selectable 100 Hz 1 kHz Operating Temperature 4 50 C Probe Thermal Stability 0 04 F S C Output Impedance 0 Output Voltage Max 13 5 VDC Output Max Current 20 mA Power Outp...

Страница 9: ...0 290 1270 User Manual P9 11 Optional Mounting Flange An optional flange for easy mounting of the CPL350 is available P017 6455 The flange attaches to the bottom of the device with four flathead screw...

Отзывы: