13
Manual ISM
–
usb.1 / .2
The following window will open. There you can select the required data transmission rate :
Note :
This is the setting for the radio receiver. Because of this the RF data rate has to be changed
in the setup window of
one
address only.
After changing the data transmission rate of the ISM - usb to 230400 baud, the following additional
commands become available in the
Service
window :
Note :
The following commands are not relevant for the radio module ISM-3i, because it is
controlled by the sensor display SD1.
Command
Description
Values ( range )
ISM-
cab1
prox
mit1
opto
mahr
dk
s233
ISM-
ISi
ISM Permanent Mode
- Maximum data rate
This determines the maximum data rate
for the transmission of the measuring
values. The maximum data rate should
not exceed 2 Hz for the mentioned radio
modules, because else the battery life
will be shortened too much.
The ISM-ISi always works with 10 Hz.
0.5 to 5 Hz
- Switch mode on/off by
pressing button
This determines how the Permanent
Mode can be activated / deactivated at
the radio module.
off / short / long
- Timeout for mode auto
disable
This determines the time for the auto-
matic deactivation of the Permanent
Mode. Relevant is the time without
change of the measuring value.
0 to 255 min
( 0 = no automatic
deactivation )
- Additional automatic
data transmission
This determines the interval in which the
radio module automatically sends a
value, even if the measuring value has
not changed.
( The time for the automatic deactivation
is not influenced by this. )
0 to 255 sec
( 0 = no data
transmission
without change
of the measuring
value )
Continued on next page.