56
PWM Signal
PWM input signal (%)
Pump condition
PWM = 0
The pump stops working
0 < PWM ≤ 5
When switched to standby mode, the pump stops operating
5 < PWM ≤ 8
If the input signal changes near the speed change point,
the hysteresis principle will prevent the pump from starting and stopping
8 < PWM ≤ 15
The pump is running at minimum speed
15 < PWM ≤ 90
The linear operation of the pump increases from minimum rotational speed
to maximum rotational speed
90 < PWM ≤ 100
The pump is running at maximum speed
Charakterystyka sygnału PWM
Transport insulation
Yes
PWM signal input frequency
200-5000 Hz
Input voltage - high level U
iH
2-24 V
Input voltage - low level U
iL
< 0,7 V
Input current - high level I
H
3,5 mA -10 mA
The operating range of the input signal
0–100%
Signal polarization
Constant
Signal line length
< 3 m
Edge rise/fall time
< T/1000
Max
Speed (RP
M)
5 10
20
30
40
50
60
70
80
90
100
PWM input signal
[%]