36
Safety of use
Precautions on use of AMG series pumps
1. Before installation, read the following manual carefully
2. Failure to observe the fragments marked with warning signs may cause bodily
injury, pump damage and other property losses, for which the producer takes no
lability, including but not limited to liability for damages.
3. The fitter, maintenance technician and user have to observe the local safety reg-
ulations.
4. The user must confirm that the installation and maintenance of the product are
performed by personnel having adequate knowledge and professional experience
connected with the structure and operation of heating systems.
5. Pumps cannot be installed in moist environment or in places which can be exposed
to flooding with splattering water.
6. To make maintenance easier, place a ball valve on both sides of the pump.
7. During installation and maintenance, cut off the electric power supply from the
pump.
8. The central heating circuit cannot be frequently refilled with non-softened water
to avoid accumulation of scale in the pipeline. High accumulation of scale can
block the rotor of the device.
9. The pump cannot be run without a heating medium.
10. If the pump is dismounted from the pipeline, either discharge the heating medium
from the system or close the ball valves cutting the pump off before dismounting
to avoid possible burning with the heating medium. Please remember that the
heating medium can have high temperature and pressure.
11. In dismounting the pump from the pipeline, the heating medium, which can have
high temperature and high pressure, will flow outside. Please be careful not to
cause bodily injury due to burning and not to flood other devices.
12. In summer or when the ambient temperature is high, pay attention to proper
ventilation in the room where the pump has been installed. It will help prevent
condensation of humidity, which can cause an electric failure.
13. In winter, if the central heating system where the pump has been installed does
not work and the ambient temperature is below 0°C, discharge water from the
heating system. Please bear in mind that freezing water can burst the pump body.
14. If the pump does not operate for a long time, close the ball valves cutting off the
pump and cut off electric power supply.
15. If the electric wire powering the pump is damaged, refer to an authorised servicing
team to replace it along with its switch.
16. If the pump motor heats up excessively (more than usually), immediately discon-
nect the pump from its power source, close he cut off valves and contact a servicing
team.