40
Installation
1
2
3
4
5
6
Permissible positioning of the control panel
1. Disconnect the pump from power supply.
2. Close the cut off valves at the inflow and outflow of the pump and perform decom-
pression;
3. Loosen and remove four bolts fixing the head in the pump body;
4. Rotate the motor into the desired position and fit four openings for bolts;
5. Insert four ampoule head screws to proper sockets and tighten them;
6. Open the valve
WARNING!!!
The heating medium can have high temperature and pressure, therefore
it is necessary to discharge the liquid from the system or close the cut-off valves on
both sides of the pump before the ampoule head screws are removed.
After the position of the pump control panel is changed, do not start it before the
heating system is efilled with the heating medium or before the cut-off valves before
and after the pump are opened.
CAUTION
Change in arrangement of the control panel
The control panel along with the motor corpus can rotate every 90°.
To change the position of the junction box, perform the following
activities: