Table 8. Capacity for models 281x-114 and 281x-214 XIV systems
Number of
modules in the
rack
Number of
interface modules
Number of data
modules
Number of disk
drives
Total usable capacity in TB
(1 TB limited capacity / 2
TB / 3 TB / 4 TB / 6 TB)
6
3
3
72
28 / 55 / 84 / 112 / 169
9
6
3
108
44 / 88 / 132 / 177 / 267
10
6
4
120
51 / 102 / 154 / 207 / 311
11
6
5
132
56 / 111 / 168 / 225 / 338
12
6
6
144
63 / 125 / 190 / 254 / 382
13
6
7
156
67 / 134 / 203 / 272 / 409
14
6
8
168
75 / 149 / 225 / 301 / 453
15
6
9
180
80 / 161 / 243 / 325 / 485
Table 9. Capacity for model 281x-314 XIV systems
Number of
modules in the
rack
Number of
interface modules
Number of data
modules
Number of disk
drives
Total usable capacity in TB
(4 TB / 6 TB)
9
6
3
108
177 / 267
10
6
4
120
207 / 311
11
6
5
132
225 / 338
12
6
6
144
254 / 382
13
6
7
156
272 / 409
14
6
8
168
301 / 453
15
6
9
180
325 / 485
Note:
DDMs in the XIV system do not need to be repaired immediately upon
failure because the XIV system is fully redundant, even with the failures.
Replacement for failed DDMs is deferred until the third DDM fails, or until
another component requires immediate onsite maintenance. For administrators, if a
DDM fails but replacement is deferred, the IBM XIV Storage Management GUI
displays the DDM as pale red, and the Status as Failed (Deferred). When there are
three or more DDMs in failed state, the IBM XIV Storage Management GUI
displays the failed DDMs as bright red, and the Status as Failed. For IBM service
representative (technicians), the IBM XIV Storage Management GUI displays the
failed DDM as bright red, and the Status as Failed regardless of whether the
replacement is deferred.
Processors and memory
The information lists the number of processors and memory that are available in
fully populated and partially populated racks.
Table 10. Processors and memory for XIV model 281x-314
Number of modules
in the rack
Number of
processors
Memory cache in GB
(4 TB / 6 TB)
SSD cache in TB
(800 GB SSD)
9
18
864
7.2
10
20
960
8.0
11
22
1056
8.8
16
IBM XIV Gen3 281x-11x, 281x-21x, and 281x-314 Planning Guide
Содержание XIV Gen3 Series
Страница 1: ...IBM XIV Storage System Gen3 Models 281x 11x 281x 21x and 281x 314 Planning Guide SC27 5412 09 IBM...
Страница 6: ...vi IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 8: ...viii IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 10: ...x IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 16: ...xvi IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 24: ...xxiv IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 52: ...28 IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 87: ...AIX 7 Oracle Solaris 11 SPARC Solaris 11 INTEL HPUX HPUX 11i v3 IA64 Chapter 8 Management tool requirements 63...
Страница 88: ...64 IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 94: ...70 IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 116: ...92 IBM XIV Gen3 281x 11x 281x 21x and 281x 314 Planning Guide...
Страница 125: ......
Страница 126: ...IBM Printed in USA SC27 5412 09...