7.
Select
Date
and
Time
from
the
menu
at
the
top
of
the
page
and
enter
the
applicable
date
and
time
information
in
the
specified
format.
8.
Select
Set
Values
to
save
the
date
and
time
settings.
The
Web/SNMP
Card
is
now
configured
for
operation
on
your
network.
See
the
online
help
for
detailed
information
about
each
menu
selection.
Using
the
Web/SNMP
card
in
serial
pass-through
mode
During
normal
operation,
the
Web/SNMP
card
controls
the
communication
path
to
the
uninterruptible
power
supply
and
provides
network-based
access
to
uninterruptible
power
supply
data
through
the
Web
and
through
SNMP.
You
can
disable
the
normal
operation
of
the
Web/SNMP
card
and
enable
serial
communication
in
a
pass-through
mode
directly
to
the
uninterruptible
power
supply.
You
can
use
serial
pass-through
mode
for
scenarios
similar
to
the
following:
v
The
uninterruptible
power
supply
firmware
requires
a
field
upgrade
and
a
9600
baud
serial
port
connection
to
the
uninterruptible
power
supply
is
required
to
perform
the
upgrade.
v
You
want
to
run
a
local
copy
of
the
Powerware
LanSafe
software
and
communicate
serially
with
the
uninterruptible
power
supply.
Before
you
begin,
go
to
http://www.powerware.com/
to
download
a
later
version
of
the
Web/SNMP
card
firmware,
if
available.
To
set
up
the
serial
pass-through
mode,
complete
the
following
steps:
1.
Change
the
dip
switch
positions
on
the
Web/SNMP
card
to
On
and
On.
The
default
is
Off
and
Off.
For
the
location
of
the
dip
switch,
see
the
illustration
on
page
27.
2.
Press
the
Web/SNMP
card
Reset
switch
to
restart
the
card
in
the
serial
pass-through
mode.
3.
Using
the
DB9-to-RJ-45
cable
that
comes
with
the
uninterruptible
power
supply,
connect
the
RJ-45
end
of
the
cable
into
the
COM
connector
on
the
Web/SNMP
card.
4.
Connect
the
DB9
end
of
the
cable
into
an
available
serial
port
on
a
workstation
or
notebook
computer.
5.
You
can
now
run
applicable
software
on
your
workstation
or
notebook
computer
and
can
communicate
serially
with
the
uninterruptible
power
supply
at
9600
baud,
8
bits,
not
parity,
and
1
stop
bit.
Note:
In
serial
pass-through
mode,
communication
through
the
Web/SNMP
Ethernet
connector
stops
and
any
existing
connections,
for
example,
to
NetWatch
software
clients
or
SNMP
management
tools,
also
stops.
6.
When
you
are
finished
using
the
Web/SNMP
card
in
serial
pass-through
mode,
disconnect
the
DB9-to-RJ-45
cable
from
the
card
and
the
workstation
or
notebook
computer.
7.
Return
the
dip
switch
to
the
original
settings.
8.
Press
the
Reset
button
to
restart
the
card.
Chapter
4.
Using
the
Web/SNMP
card
33
Содержание UPS3000 HV
Страница 1: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 2: ......
Страница 3: ...UPS3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 28: ...16 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 36: ...24 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 46: ...34 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 54: ...42 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 80: ...68 UPS 3000 LV and UPS3000 HV Installation and Maintenance Guide ...
Страница 83: ......
Страница 84: ... Part Number 40K9691 Printed in USA 1P P N 40K9691 ...