The First Block Location and the Last Block Location are both set to the number of
blocks and file marks between BOM and current logical position. If the tape is at
BOM, 0 is returned in these fields. The Beginning of Partition (BOP) flag is set if the
Block Location fields are 0. The End of Partition flag is not supported and is set to
0. The Block Position Unknown flag is always set to 0, since the position is always
known. The Partition Number, Number of Blocks in Buffer, and Number of Bytes in
Buffer are not supported and are returned as 0.
RECEIVE DIAGNOSTIC RESULTS
Table 69. RECEIVE DIAGNOSTIC RESULTS Command
7
6
5
4
3
2
1
0
0
Operation Code (1Ch)
1
Logical Unit Number (0)
Reserved
2
Reserved
3
Allocation Length
4
5
Control
The RECEIVE DIAGNOSTIC RESULTS command returns the results of diagnostic
tests to the initiator. The format of the data returned is specified in “SEND
DIAGNOSTIC” on page 65.
Chapter 2. Command Support
53
Содержание Ultrium Internal Tape Drive T200
Страница 1: ...Ultrium Internal Tape Drive Models T200 and T200F and 3580 Ultrium Tape Drive SCSI Reference WB1109 02...
Страница 2: ......
Страница 3: ...Ultrium Internal Tape Drive Models T200 and T200F and 3580 Ultrium Tape Drive SCSI Reference WB1109 02...
Страница 7: ...How to Send Your Comments 104 Trademarks 105 Index 107 Contents v...
Страница 8: ...vi Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive SCSI Reference...
Страница 12: ...x Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive SCSI Reference...
Страница 116: ...102 Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive SCSI Reference...
Страница 120: ...106 Ultrium Internal Tape Drive and 3580 Ultrium Tape Drive SCSI Reference...
Страница 125: ......
Страница 126: ...Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber...