![IBM Ultrastar 36LZX Скачать руководство пользователя страница 175](http://html1.mh-extra.com/html/ibm/ultrastar-36lzx/ultrastar-36lzx_specifications_4136210175.webp)
8.36 START/STOP Unit (1B)
LINK
FLAG
Reserved = 0
VU = 0
5
Start
LoEj
= 0
Reserved
= 0
Power Conditions = 0
4
Reserved = 0
2
3
Immed
Reserved = 0
Reserved = 0
1
Command Code = 1Bh
0
0
1
2
3
4
5
6
7
Bit
Byte
Figure 154. START/STOP Unit (1B)
The START/STOP UNIT command is used to spin up or stop the spindle motor.
Ÿ
Immed
bit is to specify
0
status is to be returned at the end of the operation
1
GOOD status shall always be returned immediately after command has been received.
The TEST UNIT READY command may be used to determine when the drive becomes
ready after a spin-up.
Ÿ
Power Conditions
is not supported by the drive and must be set to 0.
Ÿ
LoEj
is not supported by the drive and must be set to 0.
Ÿ
Start
bit is to specify:
0
stop the spindle
1
start the spindle
Note:
Once the drive has become ready (after a power on), the Start/Stop UNIT command can be used
without any errors regardless of the state of the motor: stopped or spinning.
Ultrastar 36LZX hard disk drive specifications
175
Содержание Ultrastar 36LZX
Страница 12: ...Ultrastar 36LZX hard disk drive specifications 12...
Страница 14: ...Ultrastar 36LZX hard disk drive specifications 14...
Страница 24: ...Ultrastar 36LZX hard disk drive specifications 24...
Страница 26: ...Ultrastar 36LZX hard disk drive specifications 26...
Страница 56: ...Ultrastar 36LZX hard disk drive specifications 56...
Страница 188: ...Ultrastar 36LZX hard disk drive specifications 188...
Страница 190: ...Ultrastar 36LZX hard disk drive specifications 190...
Страница 232: ...Ultrastar 36LZX hard disk drive specifications 232...