output
power
is
removed
five
minutes
after
the
power
was
disconnected
to
the
UPS.
Because
this
operation
is
controlled
by
the
SAN
Volume
Controller,
a
UPS
that
is
not
connected
to
an
active
SAN
Volume
Controller
will
not
shut
off
within
the
five-minute
required
period.
In
the
case
of
an
emergency,
you
must
manually
shut
down
the
UPS
by
pushing
the
UPS
5125
power
off
button,
or
the
UPS
5115
on/off
button.
Attention:
Data
integrity
could
be
compromised
by
pushing
the
UPS
5125
power
off
button
or
the
UPS
5115
on/off
button.
Never
shut
down
a
UPS
without
first
shutting
down
the
SAN
Volume
Controller
nodes
that
it
supports.
It
is
very
important
that
the
two
nodes
in
the
I/O
group
are
connected
to
different
uninterruptible
power
supplies.
This
configuration
ensures
that
cache
and
cluster
state
information
is
protected
in
the
event
of
a
failure
of
the
UPS
or
mainline
power
source.
When
nodes
are
added
to
the
cluster,
you
must
specify
the
I/O
group
that
they
will
join.
The
configuration
interfaces
also
checks
the
UPS
units
and
ensures
that
the
two
nodes
in
the
I/O
group
are
not
connected
to
the
same
UPS
units.
shows
a
cluster
of
four
nodes,
with
two
I/O
groups
and
two
UPS
5125
units.
Related
reference
All
controls
for
the
uninterruptible
power
supply
5115
are
located
on
the
front
panel
assembly.
All
controls
for
the
uninterruptible
power
supply
5125
are
located
on
the
front
panel
assembly.
Diagrams
of
the
hardware
for
the
uninterruptible
power
supply
(UPS)
5115
are
shown
below:
Diagrams
of
the
hardware
for
the
uninterruptible
power
supply
(UPS)
5125
are
shown
below:
Node 3
Node 4
Vdisks
Node 2
Node 1
Vdisks
I/O group 1
I/O group 2
UPS 2
UPS 1
Figure
8.
I/O
groups
and
uninterruptible
power
supply
5125
relationship
18
IBM
TotalStorage
SAN
Volume
Controller:
Installation
Guide
|
|
|
|
Содержание TotalStorage SAN Volume Controller
Страница 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Страница 8: ...vi IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 10: ...viii IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 11: ...Tables 1 Uninterruptible power supply support guidelines 17 Copyright IBM Corp 2003 2005 ix...
Страница 12: ...x IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 30: ...xxviii IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 44: ...14 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 62: ...32 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 102: ...72 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 108: ...78 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 114: ...84 IBM TotalStorage SAN Volume Controller Installation Guide...
Страница 121: ......
Страница 122: ...Part Number 64P8289 Printed in USA SC26 7541 04 1P P N 64P8289...
Страница 123: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 2 1 0...