Here is what the sense data would look like in the AS/400
Product Activity log for a model Jxx. The device type is
shown as 63A0 instead of 3592 since 63A0 is the reported type.
----------------------------------------------------------------------
Display Additional Information for Resource
Serial Resource
Name Type Model Number Name
TAPMLB46 63A0 001 13-10016 TAP04
SENSE DATA FOLLOWS. . . . :
DATA OFFSET 0 1 2 3 4 5 6 7 8 9 A B C D E F
000000 F0000300 00005058 00000000 3001FF02
000010 3A9F1000 02030191 00091040 00000800
000020 00333D00 00000000 00000000 00000000
000030 00000000 00000000 00000000 00000000
000040 00000000 49000000 36434220 20202000
Press Enter to continue.
F3=Exit F12=Cancel
OFFSET HEX ASCII DESCRIPTION
000002 03 Sense key of 3
000007 X'0A' or X'58" 18 bytes or 96 bytes of sense data are returned
00000C 3001 ASC and ASCQ
00000E FF FID (FRU identification number)
000010 3A9F 1st error code
000021 333D 2nd error code
000048 36434220 20202000 Microcode EC Number (in ASCII)
Figure 27: System i (AS/400) Product Activity Log (display)
For information about the sense bytes, see Request Sense X'03' in the IBM Tape System 3592 Hardware
Reference.
Figure 28 on page 68 provides an example of an System i hexadecimal error report printout with an error
type of Permanent.
Messages 67