DEFINE
2107-9A2
LOGICAL
CONTROL
UNIT
1
*
*
*
*********************************************************************
CNTLUNIT
CUNUMBR=7001,PATH=(70,71,72,73),UNITADD=((00,128)),
*
LINK=(24,2D,34,3D),CUADD=1,UNIT=2107
*********************************************************************
*
DEFINE
3390-9
BASE
AND
ALIASES
ADDRESS
ON
LOGICAL
CONTROL
UNIT
1
*
*
16
BASE
ADDRESS,
3
ALIASES
PER
BASE
*
**********************************************************************
IODEVICE
ADDRESS=(9100,016),CUNUMBR=(7001),STADET=Y,UNIT=3390B
IODEVICE
ADDRESS=(9150,048),CUNUMBR=(7001),STADET=Y,UNIT=3390A
**********************************************************************
**********************************************************************
*
DEFINE
2107-9A2
LOGICAL
CONTROL
UNIT
2
*
*
*
*********************************************************************
CNTLUNIT
CUNUMBR=7002,PATH=(70,71,72,73),UNITADD=((00,256)),
*
LINK=(24,2D,34,3D),CUADD=2,UNIT=2107
**********************************************************************
*
DEFINE
3390-3
BASE
AND
ALIASES
ADDRESS
ON
LOGICAL
CONTROL
UNIT
2
*
*
64
BASE
ADDRESS,
3
ALIASES
PER
BASE
*
*
*
**********************************************************************
IODEVICE
ADDRESS=(9200,064),CUNUMBR=(7002),STADET=Y,UNIT=3390B
IODEVICE
ADDRESS=(9240,192),CUNUMBR=(7002),STADET=Y,UNIT=3390A
**********************************************************************
*
DEFINE
2107-9A2
LOGICAL
CONTROL
UNIT
3
*
*
*
**********************************************************************
CNTLUNIT
CUNUMBR=7003,PATH=(70,71,72,73),UNITADD=((00,256)),
*
LINK=(24,2D,34,3D),CUADD=3,UNIT=2107
**********************************************************************
*
DEFINE
3390-3
BASE
AND
ALIASES
ADDRESS
ON
LOGICAL
CONTROL
UNIT
3
*
*
64
BASE
ADDRESS,
3
ALIASES
PER
BASE
*
*
*
**********************************************************************
IODEVICE
ADDRESS=(9300,064),CUNUMBR=(7003),STADET=Y,UNIT=3390B
IODEVICE
ADDRESS=(9340,192),CUNUMBR=(7003),STADET=Y,UNIT=3390A
**********************************************************************
*
DEFINE
2107-9A2
LOGICAL
CONTROL
UNIT
4
*
*
*
**********************************************************************
CNTLUNIT
CUNUMBR=7004,PATH=(74,75,FC,FD),UNITADD=((00,256)),
*
LINK=(24,2D,34,3D),CUADD=4,UNIT=2107
*********************************************************************
*
DEFINE
3390-3
BASE
AND
ALIASES
ADDRESS
ON
LOGICAL
CONTROL
UNIT
4
*
*
32
BASE
ADDRESS,
7
ALIASES
PER
BASE
*
*
*
**********************************************************************
IODEVICE
ADDRESS=(9400,032),CUNUMBR=(7004),STADET=Y,UNIT=3390B
IODEVICE
ADDRESS=(9420,224),CUNUMBR=(7004),STADET=Y,UNIT=3390A
**********************************************************************
102
DS8000
User’s
Guide
Содержание TotalStorage DS8000
Страница 1: ...IBM TotalStorage DS8000 User s Guide SC26 7623 03...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS8000 User s Guide SC26 7623 03...
Страница 10: ...viii DS8000 User s Guide...
Страница 12: ...x DS8000 User s Guide...
Страница 14: ...xii DS8000 User s Guide...
Страница 24: ...Department 61C 9032 South Rita Road TUCSON AZ 85775 4401 xxii DS8000 User s Guide...
Страница 26: ...xxiv DS8000 User s Guide...
Страница 50: ...24 DS8000 User s Guide...
Страница 116: ...90 DS8000 User s Guide...
Страница 120: ...94 DS8000 User s Guide...
Страница 152: ...126 DS8000 User s Guide...
Страница 166: ...140 DS8000 User s Guide...
Страница 184: ...158 DS8000 User s Guide...
Страница 186: ...160 DS8000 User s Guide...
Страница 192: ...Taiwan class A compliance statement VS07171L 166 DS8000 User s Guide...
Страница 227: ......
Страница 228: ...Printed in USA SC26 7623 03...