Diagnostic
Error
Code
FRU/Action
001-278-XXX
System
IRQ11
failure
1.
Device
on
IRQ11
2.
System
board
001-279-XXX
System
IRQ12
failure
1.
Device
on
IRQ12
2.
System
board
001-280-XXX
System
IRQ13
failure
1.
Device
on
IRQ13
2.
System
board
001-281-XXX
System
IRQ14
(hard
disk
drive)
failure
1.
Hard
disk
drive
cable
2.
Hard
disk
drive
3.
System
board
001-282-XXX
System
IRQ15
failure
1.
Device
on
IRQ15
2.
System
board
001-286-XXX
001-287-XXX
001-288-XXX
System
Timer
failure
1.
System
board
001-292-XXX
System
CMOS
RAM
error
1.
Run
Setup
and
re-test
2.
System
board
001-293-XXX
System
CMOS
Battery
1.
Battery
2.
System
board
001-298-XXX
System
RTC
date/time
update
failure
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
148
2.
System
board
001-299-XXX
System
RTC
periodic
interrupt
failure
1.
System
board
001-300-XXX
System
RTC
Alarm
failure
1.
System
board
001-301-XXX
System
RTC
Century
byte
error
1.
Flash
the
system.
See
“Flash
update
procedures”
on
page
148
2.
System
board
005-000-XXX
Video
Test
Passed
1.
No
action
005-00X-XXX
Video
error
1.
Video
card,
if
installed
2.
System
board
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX
Video
Signal
failure
1.
Video
card,
if
installed
2.
System
board
005-016-XXX
Video
Simple
Pattern
test
failure
1.
Video
Ram
2.
Video
card,
if
installed
3.
System
board
005-024-XXX
Video
Addressing
test
failure
1.
Video
card,
if
installed
2.
System
board
Chapter
7.
Symptom-to-FRU
Index
53
Содержание ThinkCentre 8127
Страница 1: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Страница 16: ...10 Hardware Maintenance Manual...
Страница 24: ...18 Hardware Maintenance Manual...
Страница 54: ...Check Verify FRU Action Check the power on switch for continuity Power on Switch 48 Hardware Maintenance Manual...
Страница 96: ...90 Hardware Maintenance Manual...
Страница 158: ...152 Hardware Maintenance Manual...
Страница 169: ...Chapter 10 Related service information 163...
Страница 170: ...164 Hardware Maintenance Manual...
Страница 171: ...Chapter 10 Related service information 165...
Страница 172: ...166 Hardware Maintenance Manual...
Страница 173: ...Chapter 10 Related service information 167...
Страница 174: ...168 Hardware Maintenance Manual...
Страница 175: ...Chapter 10 Related service information 169...
Страница 176: ...170 Hardware Maintenance Manual...
Страница 182: ...1 2 ACHTUNG Keine Gegenst nde die mehr als 82 kg wiegen auf Rack Einheiten ablegen 176 Hardware Maintenance Manual...
Страница 186: ...180 Hardware Maintenance Manual...
Страница 187: ...Chapter 10 Related service information 181...
Страница 188: ...182 Hardware Maintenance Manual...
Страница 195: ......
Страница 196: ...Part Number 74P2660 Printed in USA 1P P N 74P2660...