Diagnostic
Error
Code
FRU/Action
001-198-XXX
System
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled.
See
Chapter
5,
“Using
the
IBM
Setup
Utility,”
on
page
19
2.
Flash
the
system
and
retest.
See
“Flash
update
procedures”
on
page
148
3.
Go
to
“Undetermined
problems”
on
page
89
001-199-XXX
System
test
failed,
cause
unknown
1.
Go
to
“Undetermined
problems”
on
page
89
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
001-250-XXX
System
ECC
error
1.
System
board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System
DMA
error
1.
System
board
001-260-XXX
001-264-XXX
System
IRQ
error
1.
System
board
001-268-XXX
System
IRQ1
failure
1.
Device
on
IRQ1
2.
System
board
001-269-XXX
System
IRQ2
failure
1.
Device
on
IRQ2
2.
System
board
001-270-XXX
System
IRQ3
failure
1.
Device
on
IRQ3
2.
System
board
001-271-XXX
System
IRQ4
failure
1.
Device
on
IRQ4
2.
System
board
001-272-XXX
System
IRQ5
failure
1.
Device
on
IRQ5
2.
System
board
001-273-XXX
System
IRQ6
(diskette
drive)
failure
1.
Diskette
Cable
2.
Diskette
drive
3.
System
board
001-274-XXX
System
IRQ7
failure
1.
Device
on
IRQ7
2.
System
board
001-275-XXX
System
IRQ8
failure
1.
Device
on
IRQ8
2.
System
board
001-276-XXX
System
IRQ9
failure
1.
Device
on
IRQ9
2.
System
board
001-277-XXX
System
IRQ10
failure
1.
Device
on
IRQ10
2.
System
board
52
Hardware
Maintenance
Manual
Содержание ThinkCentre 8127
Страница 1: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Types 8127 8183 8184 8320 8416 8417 8418 8419 and 8429...
Страница 16: ...10 Hardware Maintenance Manual...
Страница 24: ...18 Hardware Maintenance Manual...
Страница 54: ...Check Verify FRU Action Check the power on switch for continuity Power on Switch 48 Hardware Maintenance Manual...
Страница 96: ...90 Hardware Maintenance Manual...
Страница 158: ...152 Hardware Maintenance Manual...
Страница 169: ...Chapter 10 Related service information 163...
Страница 170: ...164 Hardware Maintenance Manual...
Страница 171: ...Chapter 10 Related service information 165...
Страница 172: ...166 Hardware Maintenance Manual...
Страница 173: ...Chapter 10 Related service information 167...
Страница 174: ...168 Hardware Maintenance Manual...
Страница 175: ...Chapter 10 Related service information 169...
Страница 176: ...170 Hardware Maintenance Manual...
Страница 182: ...1 2 ACHTUNG Keine Gegenst nde die mehr als 82 kg wiegen auf Rack Einheiten ablegen 176 Hardware Maintenance Manual...
Страница 186: ...180 Hardware Maintenance Manual...
Страница 187: ...Chapter 10 Related service information 181...
Страница 188: ...182 Hardware Maintenance Manual...
Страница 195: ......
Страница 196: ...Part Number 74P2660 Printed in USA 1P P N 74P2660...