S.3030007
[S.3030007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3040007
[S.3040007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3050007
[S.3050007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity:
Error
User response:
Complete the following steps:
1.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
2.
Reflash UEFI image.
3.
(Trained service technician only) Replace the system board.
S.3058004
[S.3058004] A Three Strike boot failure has occurred. The system has booted with default UEFI
settings.
Explanation:
POST failure has occurred! System booted with default settings.
Severity:
Error
User response:
Complete the following steps:
1.
This event resets UEFI to the default settings for the next boot. If successful, user is forced into F1 setup. Original
UEFI settings are still present.
2.
If User did not intentionally trigger the reboots, check logs for probable cause.
3.
Undo recent system changes (settings or devices added). If not recent system changes, remove all options then
remove CMOS battery for 30 seconds to clear CMOS contents. Verify that the system boots. Then, re-install
options one at a time to locate the problem.
4.
Check IBM support site for an applicable service bulletin or firmware update that applies to this error.
5.
Reflash UEFI firmware.
6.
Remove and re-install CMOS battery for 30 seconds to clear CMOS contents
7.
(Trained service technician only) Replace the system board.
S.3030007 • S.3058004
600
System x3650 M4 BD Type 5466: Installation and Service Guide
Содержание System x3650 M4 BD Type 5466
Страница 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Страница 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 775: ...Taiwan Class A compliance statement Notices 759 ...
Страница 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 785: ......
Страница 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...