a.
Identify which release lever is labeled as the first release lever. Then
release the microprocessor release lever by pressing down on the end,
moving it to the side, and releasing it to the open (up) position.
b.
Open the second release lever on the microprocessor socket.
c.
Open the microprocessor retainer.
Attention:
Do not touch the connectors on the microprocessor and the
microprocessor socket.
3.
Install the microprocessor on the microprocessor socket:
a.
Touch the static-protective package that contains the new microprocessor
to any
unpainted
on the chassis or any
unpainted
metal surface on any other
grounded rack component; then, carefully remove the microprocessor from
the package.
b.
Release the sides of the cover and remove the cover from the installation
tool. The microprocessor is preinstalled on the installation tool.
Note:
Do not touch the microprocessor contacts. Contaminants on the
microprocessor contacts, such as oil from your skin, can cause connection
failures between the contacts and the socket.
c.
Align the installation tool with the microprocessor socket. The installation
tool rests flush on the socket only if properly aligned.
Figure 167. Microprocessor socket levers and retainer disengagement
Figure 168. Installation tool cover removal
Chapter 6. Removing and replacing components
245
Содержание System x3650 M4 BD Type 5466
Страница 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Страница 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 775: ...Taiwan Class A compliance statement Notices 759 ...
Страница 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 785: ......
Страница 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...