806f040c-2006ffff
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 6)
Explanation:
This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2006ffff or 0x806f040c2006ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-2007ffff
[PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 7)
Explanation:
This message is for the use case when an implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2007ffff or 0x806f040c2007ffff
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0131
SNMP Trap ID:
Automatically notify Support:
No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit
reached), follow the suggested actions for that error event and restart the server.
3.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory
event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the
DIMM through the Setup utility or the Advanced Settings Utility (ASU).
806f040c-2006ffff • 806f040c-2007ffff
Appendix A. Integrated management module II (IMM2) error messages
415
Содержание System x3650 M4 BD Type 5466
Страница 1: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 8: ...vi System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 102: ...86 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 130: ...114 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 178: ...162 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 189: ...v Type 2 SAS Figure 84 Cable routing Chapter 6 Removing and replacing components 173 ...
Страница 606: ...590 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 766: ...750 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 775: ...Taiwan Class A compliance statement Notices 759 ...
Страница 776: ...760 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 778: ...762 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 784: ...768 System x3650 M4 BD Type 5466 Installation and Service Guide ...
Страница 785: ......
Страница 786: ... Part Number 00KC029 Printed in USA 1P P N 00KC029 ...