Table
2.
Features
and
specifications
Microprocessor:
v
Supports
up
to
two
Intel
®
Xeon
dual-core
processors
or
two
Intel
quad-core
processors.
Important:
Do
not
mix
dual-core
and
quad-core
processors
in
the
same
system.
v
4
MB
shared
Level-2
cache
v
667,
1066,
or
1333
MHz
front-side
bus
(FSB)
Note:
Use
the
Configuration/Setup
Utility
program
to
determine
the
type
and
speed
of
the
microprocessors.
Memory:
v
Minimum:
1
GB
v
Maximum:
32
GB
(16
GB
in
mirrored
mode)
v
Types:
PC2-5300,
ECC
fully-buffered
with
double-data-rate
2
(DDR2)
SDRAM
v
Connectors:
eight
dual
inline
memory
module
(DIMM)
connectors,
two-way
interleaved
Drives
(depending
on
the
model):
v
Diskette
(optional):
External
USB
diskette
drive
v
Hard
disk
drive:
SATA
or
SAS
v
One
of
the
following
IDE
drives:
–
CD-ROM
–
CD-RW
(optional)
–
DVD-ROM
(optional)
–
DVD-ROM/CD-RW
(optional)
Drive
bays
(depending
on
the
model):
v
Three
half-high
5.25-in.
bays
(one
CD
or
DVD
drive
installed)
or
one
half-high
CD
or
DVD
and
one
full-high
tape
drive
v
Eight
3.5-in.
hot-swap
hard
disk
drive
bays
Note:
You
can
install
up
to
eight
hot-swap
drives
when
you
order
the
4-drive
backplane
option
kit.
Expansion
slots
(depending
on
the
model):
v
Six
expansion
slots
–
Three
PCI
Express
x8
slots
(two
x8
links
and
one
x4
link)
–
One
PCI
32-bit/33
MHz
slot
–
Two
PCI-X
64-bit/133
MHz
slots
Fans:
Three
speed-controlled
hot-swap
fans
(standard)
Note:
Six
fans
are
required
to
provide
redundancy
in
hot-swap
models;
therefore,
you
must
install
an
additional
redundant
power
and
cooling
option
kit
(the
option
kit
comes
with
a
hot-swap
power
supply
and
three
hot-swap
fans)
to
upgrade
to
redundant
mode.
Power
supply:
One
of
the
following
power
supplies:
v
One
nonredundant
670
watt
(90-240
V
ac)
v
One
835
watt
(90-240
V
ac).
Note:
Two
835-watt
power
supplies
provide
redundancy
in
hot-swap
models;
therefore,
you
must
install
an
additional
redundant
power
and
cooling
option
kit
(the
option
kit
comes
with
an
835-watt
hot-swap
power
supply
and
three
hot-swap
fans)
to
upgrade
to
redundant
mode.
Size:
v
Height:
440
mm
(17.3
in.)
v
Depth:
747
mm
(29.4
in.)
v
Width:
218
mm
(8.6
in.)
v
Weight:
20
kg
(42
lb)
to
34
kg
(75
lb)
depending
upon
configuration
Integrated
functions:
v
Baseboard
management
controller
(BMC)
or
onboard
service
processor
v
Broadcom
5721
10/100/1000
Ethernet
controller
on
the
system
board
with
RJ-45
Ethernet
port
v
Dual-channel
(four
ports
per
channel)
onboard
SAS/SATA
controller
v
Remote
Supervisor
Adapter
II
SlimLine
v
Two
serial
ports
v
One
parallel
port
v
Four
Universal
Serial
Bus
(USB)
v2.0
ports
(two
on
front
and
two
on
rear)
v
Keyboard
port
v
Mouse
port
v
ATA-100
single-channel
IDE
controller
(bus
mastering)
v
ATI
ES1000
video
controller
–
Compatible
with
SVGA
and
VGA
–
16
MB
SDRAM
video
memory
Acoustical
noise
emissions
(depending
on
your
model):
v
Sound
power,
idling:
5.6
bel
or
6.0
bel
v
Sound
power,
operating:
6.0
bel
or
6.1
bel
Diagnostic
LEDs:
v
Fans
v
Memory
v
Hard
disk
drives
(redundant
models)
v
Power
supply
Environment:
v
Air
temperature:
–
Server
on:
10°
to
35°C
(50°
to
95°F)
Altitude:
0
to
914
m
(2998.0
ft)
–
Server
off:
-40°
to
60°C
(-40°
to
140°F)
Altitude:
0
to
2133
m
(7000.0
ft)
v
Humidity
(operating
and
storage):
8%
to
80%
Heat
output:
Approximate
heat
output
in
British
thermal
units
(Btu)
per
hour:
v
Minimum
configuration:
781
Btu
per
hour
(229
watts)
v
Maximum
configuration:
1910
Btu
per
hour
(560
watts)
Electrical
input:
v
Sine-wave
input
(50
or
60
Hz)
required
v
Input
voltage
and
frequency
ranges
automatically
selected
v
Input
voltage
low
range:
–
Minimum:
100
V
ac
–
Maximum:
127
V
ac
v
Input
voltage
high
range:
–
Minimum:
200
V
ac
–
Maximum:
240
V
ac
v
Input
kilovolt-amperes
(kVA)
approximately:
–
Minimum:
0.23
kVA
(all
models)
–
Maximum:
0.57
kVA
Notes:
1.
Power
consumption
and
heat
output
vary
depending
on
the
number
and
type
of
optional
features
installed
and
the
power-management
optional
features
in
use.
2.
These
levels
were
measured
in
controlled
acoustical
environments
according
to
the
procedures
specified
by
the
American
National
Standards
Institute
(ANSI)
S12.10
and
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
Actual
sound-pressure
levels
in
a
given
location
might
exceed
the
average
values
stated
because
of
room
reflections
and
other
nearby
noise
sources.
The
declared
sound-power
levels
indicate
an
upper
limit,
below
which
a
large
number
of
computers
will
operate.
Chapter
1.
The
System
x3400
server
5
Содержание System x3400 Type 7975
Страница 1: ...System x3400 Types 7973 7974 7975 and 7976 User s Guide...
Страница 2: ......
Страница 3: ...System x3400 Types 7973 7974 7975 and 7976 User s Guide...
Страница 88: ...74 System x3400 Types 7973 7974 7975 and 7976 User s Guide...
Страница 126: ...112 System x3400 Types 7973 7974 7975 and 7976 User s Guide...
Страница 133: ......
Страница 134: ...Part Number 44W2584 Printed in USA 1P P N 44W2584...