Installing
an
optional
diskette
drive
To
install
an
optional
diskette
drive
in
bay
3,
complete
the
following
steps.
Note:
Only
an
optional
diskette
drive
can
be
installed
in
bay
3.
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
16.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables.
3.
Remove
the
side
cover
(see
“Removing
the
side
cover”
on
page
19).
4.
Remove
the
bezel
(see
“Removing
the
bezel”
on
page
20).
5.
Use
your
fingers
to
press
the
filler
panel
release
tab
on
the
inside
of
the
bezel
and
remove
it
from
the
bezel;
then,
pry
the
EMC
shield
away
from
the
server
with
a
screwdriver.
Store
the
filler
panel
and
EMC
shield
in
a
safe
place.
6.
Touch
the
static-protective
package
that
contains
the
drive
to
any
unpainted
metal
surface
on
the
server;
then,
remove
the
drive
from
the
package
and
place
it
on
a
static-protective
surface.
7.
Remove
the
drive
retainer
clip
(on
the
front
of
the
chassis)
for
bay
3
(see
the
illustration
on
page
27).
Slide
the
drive
retainer
clip
to
the
right
to
remove
it
from
the
chassis;
then,
snap
the
drive
retainer
clip
into
the
screw
holes
on
the
side
of
the
drive
(the
blue
side
of
the
drive
clip
should
be
facing
outward).
8.
Align
the
drive
assembly
with
the
guide
rails
in
the
bay.
Push
the
drive
into
the
bay.
9.
Connect
one
end
of
the
signal
cable
into
the
back
of
the
drive
and
make
sure
that
the
other
end
of
this
cable
is
connected
into
the
IDE
connector
on
the
system
board.
10.
Route
the
signal
cable
so
that
it
does
not
block
the
airflow
to
the
rear
of
the
drives
or
over
the
microprocessor
and
DIMMs.
11.
If
you
have
another
drive
to
install
or
remove,
do
so
now.
12.
Connect
the
power
cable
to
the
back
of
the
drive.
The
connectors
are
keyed
and
can
be
inserted
only
one
way.
If
you
have
other
devices
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Completing
the
installation”
on
page
34.
Installing
an
optional
tape
drive
To
install
a
tape
drive
in
bay
1
or
2,
complete
the
following
steps:
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
16.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables.
3.
Remove
the
side
cover
(see
“Removing
the
side
cover”
on
page
19).
4.
Remove
the
bezel
(see
“Removing
the
bezel”
on
page
20).
5.
Remove
the
filler
panel
and
EMC
shield
from
the
bay
in
which
you
want
to
install
the
tape
drive.
6.
Touch
the
static-protective
package
that
contains
the
tape
drive
to
any
unpainted
metal
surface
on
the
server;
then,
remove
the
tape
drive
from
the
package
and
place
it
on
a
static-protective
surface.
7.
Slide
the
tape
drive
into
the
drive
cage
from
the
front
of
the
server;
then,
connect
the
IDE
cable
to
the
tape
drive.
28
System
x3105
Type
4347:
User’s
Guide
Содержание System x3105 Type 4347
Страница 1: ...System x3105 Type 4347 User s Guide...
Страница 2: ......
Страница 3: ...System x3105 Type 4347 User s Guide...
Страница 66: ...54 System x3105 Type 4347 User s Guide...
Страница 70: ...58 System x3105 Type 4347 User s Guide...
Страница 71: ......
Страница 72: ...Part Number 43W7036 Printed in USA 1P P N 43W7036...