3.
Slide the replacement fiducial (
1
) into the correct magazine slot (
2
) being
sure that the fiducial tab (
6
) on each side of the fiducial is underneath the
magazine slot at
5
and above the magazine slot at
4
. Ensure that the
fiducial is not installed in the magazine slot as indicated by
7
.
4.
Slide the cartridge magazine into the library and resume normal library
operation.
Replacing the Library Enclosure
This procedure is necessary when the library enclosure, accessor, or display fails.
These components are contained within the replacement library enclosure.
Important:
Refer to the Installation Instructions that are included with the new
replacement library enclosure. Follow the procedures included in this
document for replacing the Library Enclosure, only if Installation
Instructions are not included with the new replacement library
enclosure.
The replacement library enclosure includes cartridge magazines, a power supply, a
Library Controller Card, and a packet of library foot pads. These items are
included with the replacement library enclosure due to safety agency requirements.
These unused parts will be removed from the replacement library enclosure and
returned to IBM in the defective library. The old parts currently in your defective
library will be removed, and installed into the replacement library enclosure.
Note:
To reduce the risk of personal injury or damage to equipment:
v
observe local health and safety requirements and guidelines for manual
material handling
v
obtain adequate assistance to lift and stabilize the library during
installation or removal
Minimum Installation Time
: 1 hr.
Minimum Number of Persons Required
: 2
Recommended Tools
: #2 Phillips screw driver, paper clip, blank (or scratch) data
cartridge
Preparing the Defective Library for Replacement
1.
If possible, use the Operator Control Panel to unload any drives that contain a
cartridge (
Control
>
Move Cartridges
).
2.
Power OFF the defective library.
3.
Disconnect all cables from the rear panel of the defective library.
4.
If the defective library is rack mounted, remove the two screws (
1
in
Figure 10-15 on page 10-16) from the front of the defective library anchoring the
mounting brackets on the library to the rack. With assistance, remove the
defective library from the rack.
Chapter 10. Check, Adjust, Remove, and Replace
10-15
Содержание System Storage TS3100
Страница 2: ......
Страница 12: ...x TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 16: ...xiv TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 18: ...xvi TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 30: ...xxviii TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 110: ...4 44 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 190: ...5 80 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 240: ...8 14 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 246: ...9 6 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 318: ...B 8 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 348: ...F 2 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 352: ...H 2 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 372: ...X 4 TS3100 Tape Library and TS3200 Tape Library Setup Operator and Service Guide...
Страница 373: ......
Страница 374: ...Part Number 35P2859 Printed in USA GA32 0545 12 1P P N 35P2859...