8.
Slide the file module into the rack until it snaps into place. To slide the file
module out of the rack, press on the release latches
1
.
Note:
When you move the rack cabinet, or if you install the rack cabinet in a
vibration-prone area, insert the M6 screws
2
in the front of the file module.
Attach the Ethernet cables
About this task
This task assumes that your initial planning has determined where the Ethernet
cables are to be located. The Storwize V7000 Unified control enclosure requires at
least one and a maximum of two 1 Gbps Ethernet connections to each node
canister. Refer to Figure 50 on page 90, Figure 51 on page 90, Figure 52 on page 91,
and Figure 53 on page 92; also Table 45 on page 91 and Table 46 on page 92. For
the file modules, the first two 1 Gbps Ethernet ports labeled
5
and
6
in
Figure 54 on page 93 are used for internal communications between the file
modules. The third and fourth 1 Gbps Ethernet ports are used for management
ifs00031
Figure 48. Secure the cable management arm and the file module in the rack for shipping if
needed.
ifs00032
2
1
St
or
wiz
e V
700
0 U
nif
ied
Sto
rwize V7000 U
nif
ied
Figure 49. Install the front screws.
Chapter 5. Performing the hardware installation
89
Содержание Storwize V7000
Страница 20: ...xx IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 60: ...40 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 88: ...68 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 128: ...108 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 132: ...112 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 138: ...118 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 142: ...122 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 150: ...130 IBM Storwize V7000 Unified Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073 720...
Страница 151: ......
Страница 152: ...Part Number 00MJ333 Printed in USA SC27 4223 05 1P P N 00MJ333...