594
IBM Flex System V7000 Storage Node Introduction and Implementation Guide
To generate a configuration backup using the CLI, go to the following website:
Table 13-11 describes the three files that are created by the backup process.
Table 13-11 File names created by the backup process
13.6 Software upgrade
The system upgrade process involves the upgrading of your entire IBM Flex System V7000
Storage Node environment. The amount of time can vary depending on the amount of
preparation work required and the size of the environment. In our lab we allowed ourselves an
hour but would suggest a time of around 2.5 hours.
13.6.1 Choosing an upgrade method
Before you upgrade, become familiar with the prerequisites and tasks involved. Decide
whether you want to upgrade automatically or upgrade manually. During an automatic
upgrade procedure, the clustered system upgrades each of the nodes systematically. The
automatic method is the preferred procedure for upgrading software on nodes. However, you
can also upgrade each node manually.
Upgrading the IBM Flex System V7000 Storage Node using FSM
Use the IBM FSM to update the firmware and software for IBM Flex System V7000 Storage
Node.
For more information about updating IBM Flex System V7000 Storage Node from the IBM
FSM, see the following website:
File name
Description
svc.config.backup.xml
This file contains your cluster configuration data.
svc.config.backup.sh
This file contains the names of the commands that were issued to create
the backup of the cluster.
svc.config.backup.log
This file contains details about the backup, including any error information
that might have been reported.
Note: The IBM FSM does not support updating hard disk drives on IBM Flex System
V7000 Storage Node. Information about updating hard disk drives is available at the
following website:
Note: The amount of time can vary depending on the amount of preparation work required
and the size of the environment. Generally, allow slightly over 1 hour at least for an
upgrade.
Содержание Storwize V7000
Страница 2: ......
Страница 12: ...x IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 18: ...xvi IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 20: ...xviii IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 176: ...156 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 208: ...188 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 332: ...312 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 476: ...456 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 530: ...510 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 664: ...644 IBM Flex System V7000 Storage Node Introduction and Implementation Guide...
Страница 669: ......