Table 2. Default settings for the diagnostic programs
General setup
attributes
3151 /11/
31/41
settings
3151 /51/
61
settings
3161 /64
settings
Description
Line speed
19,200
19,200
19,200
Uses the 19,200 (bits per second)
line speed to communicate with the
system unit.
Word length (bits)
8
8
8
Selects 8 bits as a data word length
(byte).
Parity
No
No
No
Does not add a parity bit and is used
together with the word length
attribute to form the 8–bit data word
(byte).
Stop bit
1
1
1
Places a bit after a data word (byte).
5. Press a key on the ASCII terminal to allow the service processor to confirm the presence of the ASCII
terminal.
6. When the login display appears for the ASMI, enter
admin
for the user ID and password.
7. Change the default password when you are prompted.
8. Press Enter until the server information appears.
You have completed the setup for an ASCII terminal, and have started the ASMI.
9. Continue with “Completing the server setup” on page 19.
Cabling the server to the HMC
The Hardware Management Console (HMC) controls managed systems, including the management of
logical partitions, the creation of a virtual environment, and the use of capacity on demand. Using service
applications, the HMC can also communicate with managed systems to detect, consolidate, and forward
information to IBM service for analysis.
Before you begin
If you have not installed and configured your HMC, do so now. For instructions, see Installation and
configuration tasks (http://www.ibm.com/support/knowledgecenter/POWER9/p9hai/
p9hai_taskflow.htm).
To manage POWER9 processor-based systems, the HMC must be at version 9 release 9.2.0, or later. To
view the HMC version and release, complete the following steps:
1. In the navigation area, click Updates.
2. In the work area, view and record the information that appears in the HMC Code Level section,
including the HMC version, release, Service Pack, build level, and base versions.
To cable the server to the HMC, complete the following steps:
Procedure
1. If you want to directly attach your HMC to the managed system, connect Ethernet Connector 1 on the
HMC to the HMC1 port on the managed system.
2. To learn how to connect an HMC to a private network so that it can manage more than one managed
system, see HMC network connections (http://www.ibm.com/support/knowledgecenter/POWER9/
p9hai/p9hai_netconhmc.htm).
Notes:
14 Power Systems: Installing the IBM Power System S922 (9009-22A and 9009-22G), IBM Power System
H922 (9223-22H), or IBM Power System H922S (9223-22S)