Table
8.
BMC
test
results
Test
Number
Status
Extended
results
Actions
166-801-
xxx
BMC
Abort
BMC
I2C
test
canceled:
the
BMC
returned
an
incorrect
response
length.
1.
Turn
off
the
system
and
disconnect
it
from
power.
The
system
must
be
removed
from
AC
power
in
order
to
reset
the
BMC.
2.
After
45
seconds,
reconnect
the
system
to
power
and
turn
on
the
system.
3.
Run
the
test
again.
4.
Make
sure
that
the
DSA
Diagnostic
code
is
at
the
latest
level.
The
latest
level
DSA
Diagnostic
code
can
be
found
on
the
IBM
Support
Web
site
at
http://www.ibm.com/
support/docview.wss?uid=psg1SERV-DSA/.
5.
Check
BMC
firmware
level
and
upgrade
if
necessary.
The
installed
firmware
level
can
be
found
in
the
DSA
Diagnostic
Event
Log
within
the
Firmware/VPD
section
for
this
component.
The
latest
level
firmware
for
this
component
can
be
found
on
the
IBM
Support
Web
site
at
http://www.ibm.com/support/us/en/.
6.
Run
the
test
again.
7.
If
the
test
continues
to
fail,
refer
to
the
other
sections
of
this
chapter
for
diagnosis
and
corrective
action.
166-802-
xxx
BMC
Abort
BMC
I2C
test
canceled:
the
test
cannot
be
completed
for
an
unknown
reason.
166-803-
xxx
BMC
Abort
BMC
I2C
test
canceled:
the
node
is
busy;
try
later.
166-804-
xxx
BMC
Abort
BMC
I2C
test
canceled:
invalid
command.
166-805-
xxx
BMC
Abort
BMC
I2C
test
canceled:
invalid
command
for
the
given
LUN.
166-806-
xxx
BMC
Abort
BMC
I2C
test
canceled:
timeout
while
processing
the
command.
166-807-
xxx
BMC
Abort
BMC
I2C
test
canceled:
out
of
space
166-808-
xxx
BMC
Abort
BMC
I2C
test
canceled:
reservation
canceled
or
invalid
reservation
ID
166-809-
xxx
BMC
Abort
BMC
I2C
test
canceled:
request
data
was
truncated.
166-810-
xxx
BMC
Abort
BMC
I2C
test
canceled:
request
data
length
is
invalid.
166-811-
xxx
BMC
Abort
BMC
I2C
test
canceled:
request
data
field
length
limit
is
exceeded.
166-812-
xxx
BMC
Abort
BMC
I2C
test
canceled:
a
parameter
is
out
of
range.
Chapter
5.
Diagnostics
and
troubleshooting
73
Содержание QS22 - BladeCenter - 0793
Страница 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 157: ......
Страница 158: ...Part Number 44R5162 1P P N 44R5162...