[root@c4b14
brcm-2.0.3-ppc]#
./
brcm_fw_nic_2.0.3-e-1_rhel5_cell.sh
-u
IBM
Ethernet
Firmware
Update
Tool,
Version
1.0.2
Warning.
No
Broadcom
NetXtreme
II
adapters
found.
ADAPTER
MAC
BOOT
IPMI
ASF
PXE
UMP
-------------------
----
----
---
---
---
001A640E030C
(5704s)
3.21
2.20
NA
NA
NA
001A640E030D
(5704s)
NA
NA
NA
NA
NA
Updating
Broadcom
NetXtreme
adapters.
Updating
001A640E030C
using
file
16A8bc.bin
--->
Update
successful
Updating
001A640E030C
using
file
16A8ipmi.bin
--->
Update
successful
Error!
Firmware
not
detected
on
device
001A640E030D.
Warning.
No
Broadcom
NetXtreme
II
adapters
found.
ADAPTER
MAC
BOOT
IPMI
ASF
PXE
UMP
-------------------
----
----
---
---
---
001A640E030C
(5704s)
3.38
2.47
NA
NA
NA
001A640E030D
(5704s)
NA
NA
NA
NA
NA
One
or
more
errors
occurred
during
the
firmware
update
process.
See
/var
Note:
The
error
message
shown
above
is
correct
as
it
refers
to
an
adapter
not
available
on
QS22.
Blade
server
Ethernet
controller
enumeration
The
enumeration
of
the
Ethernet
controller
or
controller
ports
in
a
blade
server
is
operating
system
dependent.
You
can
verify
the
Ethernet
controller
or
controller
port
designations
that
a
blade
server
uses
through
your
operating
system
settings.
The
routing
of
an
Ethernet
controller
or
controller
port
to
a
particular
BladeCenter
unit
I/O
bay
depends
on
the
type
of
Ethernet
controller
that
is
installed.
You
can
verify
which
Ethernet-controller
port
is
routed
to
which
I/O
bay
by
using
the
following
test:
1.
Install
only
one
Ethernet
switch
module
or
pass-thru
module,
in
I/O
bay
1.
2.
Make
sure
that
the
ports
on
the
switch
module
or
pass-thru
module
are
enabled
(
Switch
Tasks
→
Management
→
Advanced
Switch
Management
in
the
BladeCenter
Management
Module
Web
interface).
3.
Enable
only
one
of
the
Ethernet-controller
ports
on
the
blade
server.
Note
the
designation
that
the
blade
server
operating
system
has
for
the
controller
port.
4.
Ping
an
external
computer
on
the
network
connected
to
the
Ethernet
switch
module.
If
you
can
ping
the
external
computer,
the
Ethernet-controller
port
that
you
enabled
is
associated
with
the
switch
module
in
I/O
bay
1.
The
other
Ethernet-controller
port
in
the
blade
server
is
associated
with
the
switch
module
in
I/O
bay
2.
Communications
from
optional
I/O
expansion
cards
are
routed
to
I/O
bays
3
and
4.
If
you
have
installed
an
I/O
expansion
card
on
the
blade
server
you
can
verify
which
controller
port
on
an
expansion
card
is
routed
to
which
I/O
bay
by
performing
the
same
test,
using
a
controller
on
the
expansion
card
and
a
compatible
switch
module
or
pass-thru
module
in
I/O
bay
3
or
4.
Chapter
2.
Configuring
the
blade
server
25
Содержание QS22 - BladeCenter - 0793
Страница 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 157: ......
Страница 158: ...Part Number 44R5162 1P P N 44R5162...