1.
Reinstall
the
front
bezel
assembly
on
the
blade
server
if
removed.
See
“Installing
the
front
bezel
assembly”
for
further
information.
2.
Ensure
that
the
I/O
buffer
DIMM
slots
are
occupied
either
by
DIMMs
or
by
DIMM
fillers.
No
DIMM
fillers
are
needed
for
empty
system
memory
DIMM
slots.
3.
Replace
and
close
the
blade
server
cover,
unless
you
installed
an
optional
expansion
unit
that
has
its
own
cover.
See
“Closing
the
blade
server
cover”
on
page
52
for
further
information.
Statement
21:
CAUTION:
Hazardous
energy
is
present
when
the
blade
server
is
connected
to
the
power
source.
Always
replace
the
blade
cover
before
installing
the
blade
server.
4.
Reinstall
the
blade
server
into
the
BladeCenter
unit.
5.
Turn
on
the
blade
server.
See
“Turning
on
the
blade
server”
on
page
4
for
further
information.
6.
If
you
have
replaced
the
battery
or
the
system
board
assembly,
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
For
additional
information,
see
your
operating
system
documentation.
Note:
If
you
have
just
powered
on
the
BladeCenter
unit,
wait
until
the
power
on
LED
on
the
blade
server
flashes
slowly
before
powering
on
the
blade
server.
Installing
the
front
bezel
assembly
Figure
24
on
page
52
shows
how
to
install
the
front
bezel
assembly
on
the
blade
server.
Chapter
4.
Installing
and
removing
replaceable
units
51
Содержание QS22 - BladeCenter - 0793
Страница 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Страница 157: ......
Страница 158: ...Part Number 44R5162 1P P N 44R5162...