background image

Blade-level RAS features

The blade server has the following blade-level RAS features:

v

Automatic service processor reset and reload recovery for service processor errors

v

Automatic server recovery and restart that provides automatic reboot after boot hangs or detection of
checkstop conditions

v

Automatic server restart (ASR)

v

Built-in monitoring for temperature, voltage, hard disk drives, and flash drives

v

Call Home

v

Checkstop analysis

v

Checkstop detection with automated restart

v

Customer-upgradeable basic input/output system (BIOS) code (firmware code)

v

Customer support center 24 hours per day, 7 days a week

1

v

Degraded boot support (memory and microprocessors)

v

Repeat Gard

v

Extended Error Handling (EEH) for PCI host and root complex, PCIe link, and PCI adapter failures

v

Emergency power off (EPOW) for the blade server and expansion cards

v

Environmental monitors and alerts

v

Error codes and messages

v

ECC memory

v

Failover Ethernet support

v

First Failure Data Capture (FFDC) for determining failure root cause

v

Service processor communication with the management module to enable remote blade server
management

v

Light emitting diodes (LEDs) for identifying failing customer replaceable units (CRUs) or field
replaceable units (FRUs)

v

Light path diagnostics

v

POWER7 RAS design and objectives

v

POWER7 Hypervisor (PHYP) partition recovery or partition termination when unrecoverable errors
occur

v

Power-on self-test (POST)

v

SDRAM with serial presence detect (SPD) and vital product data (VPD)

v

System error logging

v

System Management Services (SMS) menu support

v

System-wide checkstop

v

Vital product data (VPD) unique identifiers on blade server and all major electronic components with
information stored in nonvolatile memory for remote viewing

1. Service availability will vary by country. Response time will vary depending on the number and nature of incoming calls.

8

Power Systems: Installation and User's Guide for the IBM Power PS700 (8406-70Y)

Содержание PS700

Страница 1: ...Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y GI11 9830 00 ...

Страница 2: ......

Страница 3: ...Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y GI11 9830 00 ...

Страница 4: ... Notices manual G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER7 processor and to all associated models Copyright IBM Corporation 2010 2011 US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Страница 5: ... an I O expansion card 28 Removing a CIOv form factor expansion card 29 Installing a CIOv form factor expansion card 29 Removing a combination form factor expansion card 31 Installing a combination form factor expansion card 31 Completing the installation 32 Installing and closing the blade server cover 33 Installing the blade server in a BladeCenter unit 34 Input output connectors and devices 36 ...

Страница 6: ...iv Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...

Страница 7: ...he publications package shipped with the product The booklet contains the safety information in your national language with references to the U S English source Before using a U S English publication to install operate or service this product you must first become familiar with the related safety information in the booklet You should also refer to the booklet any time you do not clearly understand...

Страница 8: ...be attached to this product to properly wired outlets v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration ...

Страница 9: ...he customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock CAUTION v Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure that air flow is not blocked or reduced ...

Страница 10: ...he weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x 2030 mm 30 x 80 in v Ensure that all devices shelves drawers doors and cables are secure v Ensure that the four leveling pads are raised to their highest position v Ensure that there is no stabilizer bracket ins...

Страница 11: ... This product might contain one or more of the following devices CD ROM drive DVD ROM drive DVD RAM drive or laser module which are Class 1 laser products Note the following information v Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device v Use of the controls or adjustments or per...

Страница 12: ...ion in the following v Network telecommunications facilities v Locations where the NEC National Electrical Code applies The intrabuilding ports of this equipment are suitable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outside plant or its wiring These inte...

Страница 13: ...e features that are not described in the documentation that comes with the blade server and the documentation might be updated occasionally to include information about those features or technical updates might be available to provide additional information that is not included in the original blade server documentation The most recent version of all BladeCenter PS700 documentation is in the Blade...

Страница 14: ...tion holes on the blade server or the BladeCenter unit Related documentation Documentation for the PS700 blade server includes documents in Portable Document Format PDF on the IBM BladeCenter Documentation CD and the online information center The most recent version of all BladeCenter documentation is in the BladeCenter information center The online BladeCenter information center is available in t...

Страница 15: ...v 32 MB of RAM v Adobe Acrobat Reader 3 0 or later or xpdf which comes with Linux operating systems Using the Documentation Browser Use the Documentation Browser to browse the contents of the CD read brief descriptions of the documents and view documents using Adobe Acrobat Reader or xpdf The Documentation Browser automatically detects the regional settings in your system and displays the document...

Страница 16: ... you avoid inconvenient or problem situations v Attention These notices indicate potential damage to programs devices or data An attention notice is placed just before the instruction or situation in which damage might occur v Caution These statements indicate situations that can be potentially hazardous to you A caution statement is placed just before the description of a potentially hazardous pr...

Страница 17: ...10 to 35 C 50 to 95 F Altitude 0 to 914 m 3000 ft Blade server on 10 to 32 C 50 to 90 F Altitude 914 m to 2133 m 3000 ft to 7000 ft Blade server off 40 to 60 C 40 to 140 F v Humidity Blade server on 8 to 80 Blade server off 8 to 80 PS700 Size v Height 24 5 cm 9 7 inches v Depth 44 6 cm 17 6 inches v Width 30 mm 1 14 inches Systems management v Supported by BladeCenter chassis management module v F...

Страница 18: ...ol that you can use to centrally manage PS700 blade server including updating the PS700 firmware For more information see the IBM Director documentation on the IBM Director CD v Impressive performance using the latest microprocessor technology The blade server comes with one POWER7 microprocessors v Integrated network support The blade server has two integrated onboard 1 gigabit per second Gbps Ho...

Страница 19: ...atures The blade server has the following component level RAS features v Alternate processor recovery v Bit steering v Chipkill memory for dual inline memory modules DIMMs v Diagnostic support of Ethernet controllers v Dual inline memory module DIMM failure isolation DIMM pair identification through unrecoverable error UE checkpointing and message related recovery actions Single DIMM identificatio...

Страница 20: ...d alerts v Error codes and messages v ECC memory v Failover Ethernet support v First Failure Data Capture FFDC for determining failure root cause v Service processor communication with the management module to enable remote blade server management v Light emitting diodes LEDs for identifying failing customer replaceable units CRUs or field replaceable units FRUs v Light path diagnostics v POWER7 R...

Страница 21: ...stem availability v Multiple operating system platform support including Microsoft Windows Server 2003 Windows 2000 Server Windows XP Professional Red Hat Linux SUSE Linux VMware Novell NetWare AIX and IBM i operating system formerly known as i5 OS For a complete list of operating systems that support IBM Director see the IBM Director Compatibility Document This document is in Portable Document Fo...

Страница 22: ...10 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...

Страница 23: ...rd also has connectors for various components Blade server control panel buttons and LEDs Blade server control panel buttons and LEDs provide operational controls and status indicators Note Figure 1 shows the control panel door in the closed normal position To access the power control button you must open the control panel door Figure 1 Blade server control panel buttons and LEDs Copyright IBM Cor...

Страница 24: ...red in the blade server The blade error LED will turn off after one of the following events v Correcting the error v Reseating the blade server in the BladeCenter unit v Cycling the BladeCenter unit power 4 Power control button This button is behind the control panel door Press this button to turn on or turn off the blade server The power control button has effect only if local power control is en...

Страница 25: ...ore you press the blade server power control button If the power on LED is flashing rapidly the service processor is initializing the blade server The power control button does not respond during initialization Note The enhanced service processor can take as long as three minutes to initialize after you install the BladeCenter PS700 blade server at which point the LED begins to flash slowly v Star...

Страница 26: ...he operating system stops functioning press and hold the power control button for more than 5 seconds to force the blade server to turn off v Use the management module to turn off the blade server The power control LED can remain on solidly for up to 1 minute after you initiate the power off process After you turn off the blade server wait until the power control LED is blinking slowly before you ...

Страница 27: ... page 16 for individual connectors Expansion unit SMP connector 3 Management card connector P1 C9 4 SAS hard disk drive connector P1 D2 5 Light Path Blue Button 6 SAS hard disk drive P1 C10 7 CIOv 1Xe expansion card connector P1 C11 8 High Speed CFFh expansion card connector P1 C12 9 DIMM 5 8 connectors See Figure 3 on page 16 for individual connectors 10 3V lithium battery connector P1 E1 Figure ...

Страница 28: ...entify the failing component Figure 4 shows the locations of LEDs on the system board Table 3 shows LED descriptions Table 3 PS700 LEDs Callout Base unit LEDs 1 3V lithium battery LED 2 DIMM 1 4 LEDs 3 Management card LED 4 Light path power LED 5 System board LED 6 HDD1 LED 7 Interposer LED Figure 3 DIMM connectors Base unit connectors Figure 4 LED locations on the system board of the PS700 blade ...

Страница 29: ...700 LEDs continued Callout Base unit LEDs 8 CIOv 1Xe expansion card connector LED 9 High Speed CFFh expansion card connector LED 10 HDD2 LED 11 DIMM 5 8 LEDs Chapter 2 Power controls indicators and connectors 17 ...

Страница 30: ...18 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...

Страница 31: ...covers and other parts in a safe place v Back up all important data before you make changes to disk drives v Before you remove a hot swap blade server from the BladeCenter unit you must shut down the operating system and turn off the blade server You do not have to shut down the BladeCenter unit itself v Blue on a component indicates touch points where you can grip the component to remove it from ...

Страница 32: ...r movement Movement can cause static electricity to build up around you v Handle the device carefully holding it by its edges or its frame v Do not touch solder joints pins or exposed circuitry v Do not leave the device where others can handle and damage it v While the device is still in its static protective package touch it to an unpainted metal part of the BladeCenter unit or any unpainted meta...

Страница 33: ...is operating shut down the operating system 3 Press the power control button behind the control panel door to turn off the blade server See Turning off the blade server on page 13 4 Wait at least 30 seconds for the hard disk drive to stop spinning 5 Open the two release handles as shown by 1 in Figure 5 The blade server moves out of the bay approximately 0 6 cm 0 25 inch 6 Pull the blade server ou...

Страница 34: ...nit on page 20 3 Carefully lay the blade server on a flat static protective surface with the cover side up 4 Press the blade cover release as shown by 1 for the base unit in Figure 6 on each side of the blade server rotate the cover on the cover pins 2 and lift the cover open 5 Lay the cover flat or lift it from the cover pins on the blade server and store the cover for future use Statement 21 CAU...

Страница 35: ...ng the blade server from a BladeCenter unit on page 20 4 Carefully lay the blade server on a flat static protective surface with the cover side up 5 Open and remove the blade server cover See Removing the blade server cover on page 22 6 Remove the drive a Pull and hold the blue release lever 1 at the front of the drive tray b Slide the drive forward 2 to disengage the connector c Lift the drive 3 ...

Страница 36: ...rver on a flat static protective surface with the cover side up 4 Open and remove the blade server cover See Removing the blade server cover on page 22 5 Locate the connector for the drive 6 Place the drive 1 into the drive tray and push it toward the rear of the blade into the connector until the drive moves past the lever at the front of the tray Attention Do not press on the top of the drive Pr...

Страница 37: ... Open and remove the blade server cover See Removing the blade server cover on page 22 5 Remove the bezel See Removing the bezel assembly 6 Locate the DIMM connector that contains the DIMM that is to be replaced Attention To avoid breaking the DIMM retaining clips or damaging the DIMM connectors open and close the clips gently 7 Carefully open the retaining clips on each end of the DIMM connector ...

Страница 38: ...omplete the following steps 1 Read the Safety topic and the Installation guidelines on page 19 2 Read the documentation that comes with the DIMMs 3 Shut down the operating system turn off the blade server and remove the blade server from the BladeCenter unit See Removing the blade server from a BladeCenter unit on page 20 4 Carefully lay the blade server on a flat static protective surface with th...

Страница 39: ...gy is present when the blade server is connected to the power source Always replace the blade server cover before installing the blade server 14 Install the blade server into the BladeCenter unit See Installing the blade server in a BladeCenter unit on page 34 Supported DIMMs Each planar in the PS700 blade server contains eight very low profile VLP memory connectors for registered dual inline memo...

Страница 40: ... that you are using is listed on the ServerProven Web site in the list of supported expansion cards for the PS700 blade server For example the following expansion cards are not supported by the PS700 blade server v BladeCenter SFF Gb Ethernet v Cisco 1X InfiniBand v Qlogic iSCSI TOE Expansion Card LFF v Broadcom 1Gb Ethernet CIOv v SAS 3Gb Expansion Card CIOv v Emulex 4Gb Fibre Channel Expansion C...

Страница 41: ... cover side up 4 Open and remove the blade server cover See Removing the blade server cover on page 22 5 Lift the expansion card 1 up and away from the 1Xe connector and out of the blade server 6 If you are instructed to return the expansion card follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing a CIOv form factor expansion card You ...

Страница 42: ...n card 1 over the system board 6 Lower the card to the system board aligning the connectors on the card with the 1Xe connector on the system board 7 Install and close the blade server cover See Installing and closing the blade server cover on page 33 Statement 21 CAUTION Hazardous energy is present when the blade server is connected to the power source Always replace the blade server cover before ...

Страница 43: ...press connector b Gently pivot the card up and out of the expansion card standoff 3 on the system board c Lift the card out of the blade server d Optional Reattach the plastic cover 1 for the PCI Express connector if it is available 5 If you are instructed to return the expansion card follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing...

Страница 44: ...Statement 21 CAUTION Hazardous energy is present when the blade server is connected to the power source Always replace the blade server cover before installing the blade server 8 Install the blade server into the BladeCenter unit See Installing the blade server in a BladeCenter unit on page 34 9 Use the documentation that comes with the expansion card to install device drivers and to perform any c...

Страница 45: ...rd requires 5 For certain optional devices run the blade server SMS Utility program as described in Using the SMS utility on page 39 Installing and closing the blade server cover Install and close the cover of the blade server before you insert the blade server into the BladeCenter unit Do not attempt to override this important protection Statement 21 CAUTION Hazardous energy is present when the b...

Страница 46: ...he blade server in a BladeCenter unit to use the blade server Statement 21 CAUTION Hazardous energy is present when the blade server is connected to the power source Always replace the blade server cover before installing the blade server Perform the following procedure to install a blade server in a BladeCenter unit 1 Go to http www ibm com systems support to download the latest firmware for the ...

Страница 47: ...omplete when the green LED stops flashing rapidly and begins to flash slowly At this point you can power on the blade server 9 Turn on the blade server See Turning on the blade server on page 13 10 Verify that the power on LED on the blade server control panel is lit continuously The continuous light indicates that the blade server is receiving power and is turned on 11 Optional Write identifying ...

Страница 48: ... panel See Blade server control panel buttons and LEDs on page 11 for information about this button and its function The Ethernet controllers on the blade server communicate with the network through the Ethernet compatible I O modules on the BladeCenter unit Network signals to and from the blade server or any expansion cards are automatically routed to a same network interface I O module through c...

Страница 49: ...module to change the boot list determine which firmware image to boot and perform other configuration tasks Updating the firmware IBM periodically makes firmware updates available for you to install on the blade server the management module or expansion cards in the blade server Important To avoid problems and to maintain proper system performance always verify that the blade server BIOS service p...

Страница 50: ...cd tmp fwupdate usr lpp diagnostics bin update_flash f 01EA3xx_yyy_zzz v Install the firmware with the update_flash command on Linux cd tmp fwupdate usr sbin update_flash f 01EA3xx_yyy_zzz v Install the firmware with the ldfware command on Virtual I O Server cd tmp fwupdate ldfware file 01EA3xx_yyy_zzz Reference codes CA2799FD and CA2799FF are displayed alternately on the control panel during the ...

Страница 51: ...evel for the PERM and the TEMP images and the image that the blade server used to start Note If the TEMP image level is more current than the PERM image commit the TEMP image See the online information center or the Problem Determination and Service Guide for information about committing the TEMP system firmware image 4 When you have verified the firmware levels press F3 until the Diagnostic Opera...

Страница 52: ...yed in the Select Device Type menu select List all Devices and select the device from that menu Creating a CE login If the blade server is running an AIX operating system you can create a customer engineer CE login to perform operating system commands that are required to service the system without being logged in as a root user The CE login must have a role of Run Diagnostics and be a primary gro...

Страница 53: ...s with the blade server For updated information about configuring the controllers see http www ibm com systems support The Ethernet controllers in your blade server support failover which provides automatic redundancy for the Ethernet controllers Failover capabilities vary per BladeCenter unit Without failover only one Ethernet controller can be connected from each server to each virtual LAN or su...

Страница 54: ...Adapter HEA that in turn provides virtual logical host Ethernet adapters LHEAs to client logical partitions LPARs The Virtual I O Server software uses LHEAs as if they were real physical adapters The logical HEAs in the PS700 blade server bypass the need for further bridging from Virtual I O Server because the LHEAs connect directly to the integrated Ethernet controllers in the blade server and fr...

Страница 55: ...d in this procedure 1 Check for the latest version of IBM Director a Go to the IBM Director download site at http www ibm com systems management director downloads html b If the drop down list shows a newer version of IBM Director than the version that comes with the blade server follow the instructions on the Web page to download the latest version 2 Install IBM Director 3 Download and install an...

Страница 56: ...44 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...

Страница 57: ...ver Ethernet controller enumeration on page 41 The documentation that comes with the Ethernet switch module that you are using v After you install the operating system on the blade server you must install any service packs or update packages that come with the operating system For additional information see the instructions that come with your operating system documentation and the service packs o...

Страница 58: ...itioning to create client partitions for client operating systems v Installing Linux You can install a Linux operating system by following the installation instructions in the IBM Systems Information Center The online Linux installation instructions are available in the Linux on BladeCenter JS22 topic in the IBM Systems Information Center v Installing IBM i You can install the IBM i operating syst...

Страница 59: ...CD The Service and productivity tools for Linux on POWER systems site describes how to create a CD The hardware diagnostic aids and productivity tools are required for such hardware reliability availability and serviceability RAS functions as first failure data capture and error log analysis With the tools installed problem determination and correction are greatly enhanced and the likelihood of an...

Страница 60: ...48 Power Systems Installation and User s Guide for the IBM Power PS700 8406 70Y ...

Страница 61: ... a SOL connection chcons dev vty0 shutdown Fr The commands do not affect the console that is used by partition firmware The following tools are available to help you diagnose and solve hardware related problems v Power on self test POST firmware checkpoints and error codes The firmware checkpoints are progress codes that your blade server writes to the management module event log during POST See t...

Страница 62: ...ing system See your operating system documentation for more information v Light path diagnostics Use light path diagnostics LEDs on the system board to identify system errors If the system error LED on the system LED panel on the front or rear of the BladeCenter unit is lit one or more error LEDs on the BladeCenter unit components also might be lit These LEDs help identify the cause of the problem...

Страница 63: ...ted in new editions of the publication The manufacturer may make improvements and or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to Web sites not owned by the manufacturer are provided for convenience only and do not in any manner serve as an endorsement of those Web sites The materials at those Web sites...

Страница 64: ...ust establish procedures to ensure that there is independent data verification before relying on such data in sensitive or critical operations Users should periodically check the manufacturer s support websites for updated information and fixes applicable to the system and related software Ethernet connection usage restriction This product is not intended to be connected directly or indirectly by ...

Страница 65: ...ions to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Industry Canada...

Страница 66: ...take corrective actions Japanese Electronics and Information Technology Industries Association JEITA Confirmed Harmonics Guideline products less than or equal to 20 A per phase Japanese Electronics and Information Technology Industries Association JEITA Confirmed Harmonics Guideline with Modifications products greater than 20 A per phase Electromagnetic Interference EMI Statement People s Republic...

Страница 67: ...Taiwan statement above Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures IBM Taiwan Contact Information Electromagnetic Interference EMI Statement Korea Appendix Notices 55 ...

Страница 68: ...all kann vom Betreiber verlangt werden angemessene Maßnahmen zu ergreifen und dafür aufzukommen Deutschland Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten Dieses Produkt entspricht dem Gesetz über die elektromagnetische Verträglichkeit von Geräten EMVG Dies ist die Umsetzung der EU Richtlinie 2004 108 EG in der Bundesrepublik Deutschland Zulassungsbescheinigung lau...

Страница 69: ...y turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures v Reorient or relocate the receiving antenna v Increase the separation between the equipment and receiver v Connect the equipment into an outlet on a circuit different from that to which the receiver is connected v Consult an IBM authorized dealer or service represe...

Страница 70: ...n of the product including the fitting of non IBM option cards This product has been tested and found to comply with the limits for Class B Information Technology Equipment according to European Standard EN 55022 The limits for Class B equipment were derived for typical residential environments to provide reasonable protection against interference with licensed communication equipment European Com...

Страница 71: ...die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen wenn das Produkt ohne Zustimmung von IBM verändert bzw wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt eingebaut werden Deutschlan...

Страница 72: ... provided that all proprietary notices are preserved You may not make derivative works of these publications or reproduce distribute or display these publications or any portion thereof outside your enterprise without the express consent of the manufacturer Except as expressly granted in this permission no other permissions licenses or rights are granted either express or implied to the publicatio...

Страница 73: ......

Страница 74: ... Part Number 16R2906 Printed in USA GI11 9830 00 1P P N 16R2906 ...

Отзывы: