Scheduling a server shut down or restart

Procedure

1.

Select the

System

view.

2.

In the left pane, expand the Site Node for the SiteProtector SP1001 appliance
Site, and then click the

Appliance

icon. The Appliance Configuration interface

appears in the right pane.

3.

Select the

Maintenance

tab, and then click

Shutdown

.

4.

Select one of the following options:

Click this option...

To do the following...

Restart scheduled

Schedule the SiteProtector SP1001 appliance
to restart

Shutdown scheduled

Schedule the SiteProtector SP1001 appliance
to shut down, and then turn off

5.

Select either the

elapsed time

option or the

day and time

option, and then

enter the desired values.

6.

If you want to warn users before the shut down occurs, select the

Send

warning message to computers currently connected to this server

check box.

7.

Click

OK

.

Configuring SNMP Services

About this task

By default, the Simple Network Management Protocol (SNMP) service is disabled
on the SiteProtector SP1001 appliance but allowed by the Proventia Server IPS
policy. If your SiteProtector SP1001 appliance must be monitored by SNMP, you
can enable SNMP services on the Network tab.

SNMP is a network management protocol frequently used in TCP/IP networks to
monitor and manage computers and other devices (such as printers) connected to
the network.

Procedure

1.

Select the

System

view.

2.

In the left pane, expand the Site Node for the SiteProtector SP1001 appliance
Site, and then click the

Appliance

icon.

3.

The Appliance Configuration interface appears in the right pane.

4.

Select the

Network

tab, and then click

SNMP Service

.

5.

Do one of the following:

v

To enable SNMP services, select the

SNMP Service Enabled

check box.

v

To disable SNMP services, clear the

SNMP Service Enabled

check box.

6.

Click

OK

.

Chapter 5. Optional Configuration Tasks

27

Содержание Proventia Management SiteProtector SP1001

Страница 1: ...IBM Proventia Management SiteProtector SP1001 Hardware Configuration Guide Version 2 0 Service Pack 7 0...

Страница 2: ......

Страница 3: ...IBM Proventia Management SiteProtector SP1001 Hardware Configuration Guide Version 2 0 Service Pack 7 0...

Страница 4: ...Copyright Statement Copyright IBM Corporation 1994 2008 IBM Global Services Route 100 Somers NY 10589 U S A Produced in the United States of America All Rights Reserved...

Страница 5: ...s disclaims all warranties either expressed or implied including the warranties of merchantability and fitness for a particular purpose In no event shall IBM ISS be liable for any damages whatsoever i...

Страница 6: ...iv SiteProtector System SP1001 Hardware Configuration...

Страница 7: ...municate with the Network 15 Entering Network Information 16 Installing and Starting the SiteProtector Console 17 Installing the SiteProtector Console 17 Starting the SiteProtector Console and logging...

Страница 8: ...vi SiteProtector System SP1001 Hardware Configuration...

Страница 9: ...mpanion to the SiteProtector documentation suite After you have configured the SiteProtector SP1001 appliance hardware use the SiteProtector Configuration Guide to configure the SiteProtector security...

Страница 10: ...procedures for configuring the SiteProtector SP1001 appliance administration options using the SiteProtector Console If you configured the SiteProtector SP1001 appliance hardware using the SiteProtec...

Страница 11: ...ts and Appliances Contains information about agents and appliances that work with SiteProtector Related publications The user documents for SiteProtector and related products are available as portable...

Страница 12: ...port The following table provides hours for Technical Support at the Americas and other locations Location Hours Americas 24 hours a day All other locations Monday through Friday 9 00 A M to 6 00 P M...

Страница 13: ...d under certain conditions To avoid these hazards ensure that your system electrical requirements do not exceed branch circuit protection requirements Refer to the information that is provided with yo...

Страница 14: ...t signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you...

Страница 15: ...overcurrent protection To provide the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit...

Страница 16: ...mation contained in product publications to be presented in their national languages If this requirement applies to your country a safety information booklet is included in the publications package sh...

Страница 17: ...class 1 laser product Consult the label on each part for laser certification numbers and approval information Product recycling and disposal This unit must be recycled or discarded according to applic...

Страница 18: ...vailable to customers for the return recycling and recovery of WEEE Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potentia...

Страница 19: ...pean Directive 2006 66 EC concerning batteries and accumulators and waste batteries and accumulators The Directive determines the framework for the return and recycling of used batteries and accumulat...

Страница 20: ...apply to this IBM product The statement for other IBM products intended for use with this product will appear in their accompanying manuals Federal Communications Commission FCC Statement Note This eq...

Страница 21: ...ion Technology Equipment according to European Standard EN 55022 The limits for Class equipment were derived for commercial and industrial environments to provide reasonable protection against interfe...

Страница 22: ...36 f r Ger te der Klasse A Dieses Ger t ist berechtigt in bereinstimmung mit dem Deutschen EMVG das EGKonformit tszeichen CE zu f hren Verantwortlich f r die Konformit tserkl rung nach Paragraf 5 des...

Страница 23: ...Korean Class A Compliance Statement Overview xxi...

Страница 24: ...xxii SiteProtector System SP1001 Hardware Configuration...

Страница 25: ...introduces the SiteProtector SP1001 appliance and describes the components and functions of SiteProtector Topics What is the SiteProtector SP1001 Appliance on page 2 SiteProtector Components on page 3...

Страница 26: ...ent on a separate computer v IBM Proventia Server Intrusion Prevention System IPS for Windows which provides host security protection for the SiteProtector SP1001 appliance SiteProtector components by...

Страница 27: ...the status of X Press Updates XPUs SP Core The SP core includes the following components v The Application Server which includes the Sensor Controller component enables communication between the SiteP...

Страница 28: ...y of the SiteProtector components and agents on computers on your network Event Viewer optional The SiteProtector Event Viewer receives unprocessed events from the Event Collector to provide near real...

Страница 29: ...ure Description Intrusion prevention Proventia Server IPS includes an intrusion prevention system that alerts you to attacks and blocks threats to the SiteProtector SP1001 appliance and to your networ...

Страница 30: ...6 SiteProtector System SP1001 Hardware Configuration...

Страница 31: ...ation checklists Review this information before you install the SiteProtector SP1001 appliance hardware in a rack or connect the SiteProtector SP1001 appliance to a network Topics Requirements and Con...

Страница 32: ...m of the SiteProtector SP1001 appliance This sticker may become inaccessible if you install the SiteProtector SP1001 appliance in a rack Important If you need to restore the SiteProtector SP1001 appli...

Страница 33: ...nter which is accessible over the Internet For more information about product issues and updates see the IBM ISS Download Center at http www iss net Proventia Server IPS Proventia Server IPS is design...

Страница 34: ...mask value for the network connected to the management port Example 255 255 255 0 h Your setting h Management port default gateway The IP address for the management gateway Example 192 168 1 1 h Your...

Страница 35: ...arted Card instead of the procedures in this chapter if you are an experienced network administrator and you anticipate that your configuration will be straightforward The SiteProtector SP1001 Getting...

Страница 36: ...tion See Pre configuration Checklists on page 10 Checklist Use the checklist in the following table as a guide to help you perform the tasks in this chapter The check boxes are provided as a convenien...

Страница 37: ...tures of the front panel Feature Description LCD controller module The LCD controller module or LCD panel allows the user to set up the network configuration You can also configure the following from...

Страница 38: ...port The DVI port lets you connect the SiteProtector SP1001 appliance to a digital monitor Power button The power button turns the SiteProtector SP1001 appliance on and off VGA port The VGA port lets...

Страница 39: ...eProtector SP1001 appliance s host name or the IP address after the appliance has established communication with an external device To do so will prevent the SiteProtector SP1001 appliance from commun...

Страница 40: ...iguration menu and then go to Step 7 v If no enter the IP address of the SiteProtector SP1001 appliance in the field provided Note Press UP or DOWN to select a number and then use the LEFT or RIGHT bu...

Страница 41: ...onsole on your computer About this task Installing the SiteProtector Console Procedure 1 Click Start on the task bar and then select Programs Internet Explorer 2 Type the following https appliance_IP_...

Страница 42: ...4 Log in using the SiteProtector SP1001 appliance s IP address that you entered when you performed the procedure on 26 5 Do the following In this Field Type the following User Name Administrator Pass...

Страница 43: ...orm these tasks Important If you used the procedures in the SiteProtector SP1001 Getting Started Card to connect the SiteProtector SP1001 appliance start here to continue the configuration process Top...

Страница 44: ...ks use the check boxes to check off the tasks that you have completed U Task Description h 1 Install the license files for the reporting correlation and security features See Installing License Files...

Страница 45: ...fore you begin Install the SecurityFusion module before you install the license file for this add on component See the SiteProtector SecurityFusion Module Guide for detailed information Procedure 1 In...

Страница 46: ...and then click OK The SiteProtector SP1001 appliance restarts Securing SP1001 Appliance Passwords Now that you have logged on to the SiteProtector Console and installed the license files you must sec...

Страница 47: ...tting the Date and Time About this task By default the SiteProtector SP1001 appliance uses Windows time synchronization to update its date and time settings However you should verify that these settin...

Страница 48: ...24 SiteProtector System SP1001 Hardware Configuration...

Страница 49: ...ional hardware and Windows administration options on the SiteProtector SP1001 appliance Topics Starting and Shutting Down the SiteProtector SP1001 on page 26 Configuring SNMP Services on page 27 Secur...

Страница 50: ...or SP1001 appliance to turn it on again You cannot use the SiteProtector Console to turn on the SiteProtector SP1001 appliance Procedure 1 Select the System view 2 In the left pane expand the Site Nod...

Страница 51: ...r check box 7 Click OK Configuring SNMP Services About this task By default the Simple Network Management Protocol SNMP service is disabled on the SiteProtector SP1001 appliance but allowed by the Pro...

Страница 52: ...ce LCD settings you can require that users specify a PIN to access the LCD panel Procedure 1 On the LCD panel press the ENTER button The Appliance PIN screen appears 2 On the Appliance PIN screen pres...

Страница 53: ...ins information that can help you troubleshoot the SiteProtector SP1001 appliance hardware and Windows administration options Topics Restoring Factory Defaults on page 30 Issue Related to the LCD Pane...

Страница 54: ...ector SP1001 appliance Perform this procedure only when it is absolutely necessary to recover from a catastrophic failure Procedure 1 Restart the SiteProtector SP1001 appliance Note See Starting and S...

Страница 55: ...e to network settings fails Description If you are trying to change the network settings in the LCD panel while a window that contains the network configuration options is open on the SiteProtector Co...

Страница 56: ...32 SiteProtector System SP1001 Hardware Configuration...

Страница 57: ...s appendix describes the configuration options that you can use to configure the SiteProtector SP1001 appliance Some of these options are described in more detail in other chapters in this guide Topic...

Страница 58: ...page or the Welcome page This option allows you to choose which page the server displays first Network configuration options You can also edit or view other network SiteProtector SP1001 appliance opti...

Страница 59: ...properties of each share Enable configure and disable file sharing protocols Maintenance Set the date and time on the server View clear download and configure the Application System or Security logs...

Страница 60: ...36 SiteProtector System SP1001 Hardware Configuration...

Страница 61: ...Certificate of Authenticity 30 P password administrator 22 Product Key important consideration for rack mounted appliances 8 R remote desktop 9 S safety notices xi shut down send warning message befor...

Страница 62: ...38 SiteProtector System SP1001 Hardware Configuration...

Страница 63: ......

Страница 64: ...Printed in USA...

Отзывы: