Attention:
Three people are required to safely lift the expansion unit. Using fewer than three
people to lift the expansion unit can result in injury.
d.
Slide the expansion unit into the rack.
e.
Install the two M5 securing screws
(J)
through the expansion unit and into the nut clips on the left
and right rails. See the previous figure.
f.
Install the bezel
(L)
onto the expansion unit. Press the bezel into place and secure it with two M5
screws
(M)
on the left and right rails. See the following figure.
g.
Insert the service information holder
(N)
into the slot in the bezel.
Figure 8. Installing the expansion unit into a rack
Figure 9. Installing the bezel and service information holder
10
Power Systems: Installing the 5802 and 5877 expansion units