Chapter 7. Solving problems
131
202
System cache
Aborted
Test setup error: BIOS cannot access VPD
information
If your server does not
have the latest level
BIOS installed, update
the BIOS to the latest
level and run the
diagnostic program
again.
If the problem persists,
call for service.
Test setup error: Corrupt DMI BIOS. Information
in BIOS is not as expected
Test setup error: No L2 cache detected on
microprocessor socket id xyz or BIOS setup
problem
(where xyz identifies the microprocessor that is
causing the error message)
1. If your server does
not have the latest
level BIOS
installed, update
the BIOS to the
latest level
2. Run the diagnostic
program again.
3. If the problem
remains, replace
the failing
processor.
If the problem persists,
call for service.
Test setup error: Unknown hardware problem
associated with microprocessor in socket id xyz.
(where xyz identifies the microprocessor that is
causing the error message)
Failed
Microprocessor in socket ID xyz
(where xyz identifies the microprocessor that is
causing the error message)
Note:
The indicated microprocessor LED will
be on.
1. Reseat the
identified
microprocessor.
2. If the problem
remains, replace
the
microprocessor.
If the problem persists,
call for service.
Warning
Test setup error: Cache is disabled. Use system
setup to enable before retrying the test
Use the Cache Control
choice from the
Advanced Setup menu
to enable the cache.
If the problem persists,
call for service.
206
Diskette drive
Failed
Internal diskette drive bay
Call for service.
215
CD-ROM
Aborted
The CD-ROM drive is not present.
Verify that the cables
are properly
connected to the CD-
ROM drive.
If the problem persists,
call for service.
Failed
On system board.
Call for service.
217
Hard disk drive Failed
BIOS drive # n (where n is the drive bay number) Call for service.
Code
Function
Result
Text message
Action
Table 17. Diagnostic error messages
Содержание Netfinity 4500R
Страница 1: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Страница 2: ......
Страница 3: ...IBM IBM Netfinity 4500R User s Reference SC19 K080 60...
Страница 10: ...viii IBM Netfinity 4500R User s Reference Safety...
Страница 32: ...20 IBM Netfinity 4500R User s Reference Using the SCSISelect utility program...
Страница 70: ...58 IBM Netfinity 4500R User s Reference Netfinity Manager...
Страница 118: ...106 IBM Netfinity 4500R User s Reference Input Output ports...
Страница 192: ...180 IBM Netfinity 4500R User s Reference...
Страница 196: ...184 IBM Netfinity 4500R User s Reference...
Страница 197: ......