(CL2) #config
(CL2)(config)#interface 0/13-0/16
(CL2)(interface 0/13-0/16)#no shutdown
(CL2) #show port-channel 3/1
Local Interface................................ 3/1
Channel Name................................... ISL-LAG
Link State..................................... Up
Admin Mode..................................... Enabled
Type........................................... Static
Load Balance Option............................ 7
(Enhanced hashing mode)
Mbr
Device/
Port
Port
Ports
Timeout
Speed
Active
------ ------------- --------- -------
0/13
actor/long
10G Full
True
partner/long
0/14
actor/long
10G Full
True
partner/long
0/15
actor/long
10G Full
True
partner/long
0/16
actor/long
10G Full
True
partner/long
10.
Bring up the ports on the newCL1 switch that are associated with the cluster
nodes.
This example brings up ports 1 through 12 on the newCL1 switch:
(newCL1) #config
(newCL1)(config)#interface 0/1-0/12
(newCL1)(interface 0/1-0/12)#no shut
11.
On a single node, bring up the cluster node port e1a connected to newCL1
and confirm that the link to e1a is
up
.
This example brings up port e1a on node1 and displays information about the
ports, verifying that e1a is
up
:
cluster::*> network port modify -node node1 -port e1a -up-admin true
cluster::*> network port show -role cluster
Auto-Negot
Duplex
Speed (Mbps)
Node
Port Role
Link MTU
Admin/Oper
Admin/Oper Admin/Oper
------ ---- -------- ---- -----
----------- ---------- ------------
node1
e1a
cluster
up
9000
true/true
full/full
auto/10000
e2a
cluster
up
9000
true/true
full/full
auto/10000
12.
On that same node, node1, use
network interface revert
to revert the cluster
LIF associated with the port in the previous step. In this example, the LIFs are
successfully reverted if the Home value is
true
and the port is e1a.
The following commands return the LIFs on
clus1
(
node1
) to their home ports
and display information about the LIFs on
node1
.
Using the cluster and management switch procedures
25
Содержание N Series
Страница 1: ...IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide SC27 6293 00...
Страница 2: ......
Страница 4: ...iv IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 6: ...2 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 16: ...12 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 18: ...14 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 32: ...28 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 40: ...36 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 42: ...38 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 43: ......
Страница 44: ...NA 210 06778_A0 Printed in USA SC27 6293 00...