(CN1610) #write memory
This operation may take a few minutes.
Management interfaces will not be available during this time.
Are you sure you want to save? (y/n) y
Config file ’startup-config’ created successfully.
Configuration Saved!
Make sure to save the
running-config
file to a script so that it can be used
later if you want to reconfigure the switch to the current settings.
7.
Save the script for future use if it is needed to reconfigure the switch to the
current settings by using the
show running-config running-config.scr
command. You can give the
running-config.scr
file any name you want, but
it must have the
.scr
extension.
(CN1610) #show running-config running-config.scr
Config script created successfully.
8.
To verify that the script is saved, use the
script list
command.
(CN1610) #script list
Configuration Script Name
Size(Bytes)
--------------------------------
-----------
running-config.scr
6960
1 configuration script(s) found.
2041 Kbytes free.
9.
Download the image from the TFTP server to the CN1610 switch with
copy
tftp
command. In this example, enter
copy tftp://
tftpserver
/
NetApp_CN1610_1.0.0.4.stk active
.
tftpserver
is the name of the TFTP server;
NetApp_CN1610_1.0.0.4.stk
is the name of the image. This command
downloads the new image to the flash, which takes a few minutes to
complete. During this time the current active image is still operational.
(CN1610) #
copy tftp://
tftpserver
/NetApp_CN1610_1.0.0.4.stk active
10.
Use the
show version
command to verify the version of the image
downloaded to the flash.
(CN1610) #show version
Switch: 1
System Description............................. NetApp CN1610, 1.0.0.4, Linux
2.6.21.7
Machine Type................................... NetApp CN1610
Machine Model.................................. CN1610
Serial Number.................................. 10611100037
Burned In MAC Address.......................... 00:A0:98:4B:AB:DB
Software Version............................... 1.0.0.2
System......................................... Linux 2.6.21.7
Network Processing Device...................... BCM56820_B0
Part Number.................................... 111-00893
Additional Packages............................ FASTPATH QOS
FASTPATH IPv6 Management
11.
To verify that the download of the image was successful, enter the
show
bootvar
command. The
active
and
next-active
images are the “desired now”
and the “new desired image” versions, which are both
1.0.0.4
in the
command output. This is before the switch reboot.
Using the cluster and management switch procedures
21
Содержание N Series
Страница 1: ...IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide SC27 6293 00...
Страница 2: ......
Страница 4: ...iv IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 6: ...2 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 16: ...12 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 18: ...14 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 32: ...28 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 40: ...36 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 42: ...38 IBM System Storage N series Clustered Data ONTAP Switch Setup and Configuration Guide...
Страница 43: ......
Страница 44: ...NA 210 06778_A0 Printed in USA SC27 6293 00...