78
Error messages
Error messages
This section includes some error messages for problems commonly seen when
users new to native disk shelves on gateways set up their systems. This section is
not meant to describe all possible reasons why a particular error message is
generated.
Message
Explanation
PANIC: sanown: received add for already known
disk in process sanown_notify on release
Release <release name> on <date and timestamp>
If you are using Multipath Storage for disks
on a gateway HA pair, and you do not set the
gateway boot environment variable (
fc-non-
array-adapter-list
), this message is issued
and the gateway panics. See “
gateway environment variable for Multipath
Storage
” on page 71 for instructions.
Note
This message is issued in other circumstances
that are not related to Multipath Storage on
the gateway—for example, when array LUN
IDs are duplicated.
[cf.nm.nicTransitionDown:warning]: Cluster
Interconnect link 0 is DOWN
Tue Oct 16 17:25:28 GMT
[cf.rv.notConnected:error]: Connection for
cfo_rv failed Tue Oct 16
17:25:48 GMT [esh.auto.term.error:error]: AUTO
TERMINATION ERROR: TERM switch set improperly
on ESH A on channels 0b/0d disk shelf ID 1.
Tue Oct 16 17:25:48 GMT
[esh.speed.error:error]: Disk shelf previously
connected to the OUT port of ESH A on channels
0b/0d disk shelf ID 1 is now inaccessible.
(Check cables, speed selection.)
You might see this error message when there
is a loop speed mismatch for components on
the same loop. The Gb-loop speed for all
components must be set to the lowest of any
component in the loop.
Содержание N Series
Страница 6: ...vi Notices...
Страница 14: ...xiv Preface...
Страница 21: ...Chapter 1 Implementation Overview 7 See SnapLock Compliance aggregates on page 22 for more information...
Страница 28: ...14 Understanding storage provided by native disk shelves...
Страница 78: ...64 Configuring Gateway Ports as Initiators...
Страница 98: ...84 Reinstalling the system...
Страница 104: ......
Страница 105: ...NA 210 04520_A0 Printed in USA GC27 2188 03...