72
Configuring the gateway environment variable for Multipath
S
torage
Step
Action
1
Verify that the FC ports on both vs1 and vs2 are set as initiators.
Configuring Gateway Ports as Initiators
page 63 for instructions.
To set the environment variable on vs2
2
On vs1, enter the following command to force vs1 to take over vs2:
cf takeover
3
On vs2, interrupt the boot process by pressing Ctrl-C when you see
the following message on the console:
Starting AUTOBOOT press Ctrl-C to abort
4
On vs2, enter the following command to check which FC initiator
ports are already specified:
printenv fc-non-array-adapter-list
If no FC initiator ports have been specified, the following appears on
the screen:
Variable Name
Value
---------------------------------------------------
fc-non-array-adapter-list ** Undefined ***