1-24
TS3400 Tape Library Maintenance Information
34
Download fail
Set when an FMR image is
unsuccessfully downloaded to the tape
drive via the Fibre Channel or RS-232
interface. It is cleared when the drive is
powered OFF or a successful microcode
update is performed.
Cycle the power and try again.
If firmware is not the current version,
update the firmware. See “Methods of
Updating Firmware” on page 7-20.
36
Drive temperature
Set when the drive temperature sensor
indicates that the drive is too hot.
Cycle the power and try again.
If problem persists, replace the drive
canister. See “Replacing a Tape Drive
Canister or FC 1663 Tape Drive
Removal” on page 9-11.
37
Drive voltage
Set when the drive detects power
supply voltages outside of the specified
voltage limits. It is cleared when the
drive is powered OFF.
Cycle the power and try again.
If problem persists, replace the drive
canister. See “Replacing a Tape Drive
Canister or FC 1663 Tape Drive
Removal” on page 9-11.
38
Predictive failure
Set when a hardware failure of the tape
drive is predicted.
Cycle the power and try again.
If problem persists, replace the drive
canister. See “Replacing a Tape Drive
Canister or FC 1663 Tape Drive
Removal” on page 9-11.
39
Diagnostics required
Set when a tape cartridge or drive FID
or ATTN DRV message is posted. The
flag is cleared when the drive is
powered OFF.
Try different media.
Run drive diagnostic tests.
50
Lost statistics
Set when media statistics were lost at
some time in the past.
None. Status only.
51
Tape directory invalid
at unload
Set when the tape directory on the tape
cartridge that was previously unloaded
is corrupted. The file-search
performance is degraded.
Use your backup software to rebuild the
tape directory by reading all the data.
52
Tape system area write
failure
Set when the tape cartridge that was
previously unloaded could not write its
system area successfully.
Try another cartridge.
53
Tape system area read
failure
Set when the tape system area could not
be read successfully at load time.
Try another cartridge.
54
No start of data
Set when the start of data could not be
found on the tape.
Try another cartridge.
55
Load failure
The operation failed because the media
cannot be loaded and threaded.
Remove the cartridge and try another.
Table 1-6. TapeAlert flags supported by the 3592 tape drives (continued)
Flag
Number
Flag Name
Description
Action Required
Содержание L5U
Страница 1: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03...
Страница 2: ......
Страница 3: ...IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577 GA32 0572 03...
Страница 6: ...iv TS3400 Tape Library Maintenance Information...
Страница 14: ...xii TS3400 Tape Library Maintenance Information...
Страница 52: ...1 36 TS3400 Tape Library Maintenance Information...
Страница 84: ...3 14 TS3400 Tape Library Maintenance Information...
Страница 92: ...4 8 TS3400 Tape Library Maintenance Information...
Страница 106: ...5 14 TS3400 Tape Library Maintenance Information...
Страница 109: ...Chapter 6 Installing the Library 6 3 Figure 6 1 Components removed to reduce weight a34z0177...
Страница 194: ...8 40 TS3400 Tape Library Maintenance Information...
Страница 260: ...11 8 TS3400 Tape Library Maintenance Information...
Страница 266: ...12 6 TS3400 Tape Library Maintenance Information...
Страница 274: ...B 2 TS3400 Tape Library Maintenance Information...
Страница 293: ......
Страница 294: ...Part Number 45E5263 Printed in USA GA32 0572 03 1P P N 45E5263...
Страница 295: ...Spine information IBM System Storage TS3400 Tape Library Maintenance Information Machine Type 3577...