Step 4
This step attempts to load the Standalone diagnostics.
1. Turn off the power.
2. Turn on the power.
3. Insert the diagnostic CD-ROM into the CD-ROM drive.
4. If the keyboard indicator displays, press F5 on the directly attached keyboard, or 5
on the ASCII keyboard, to indicate that diagnostics are to be loaded.
5. Enter any requested passwords.
6. Follow any instructions to select a console.
7. Wait until the diagnostics load or the system appears to stop.
Did the diagnostics load?
NO
Go to “Step 5”.
YES
Go to “Step 6” on page 156.
Step 5
Starting at the top of the following table, find your symptom and follow the instructions
given in the Action column.
Symptom
Action
The power LED does not come on, or comes
on and does not stay on.
Check the power cable to the outlet. Check the
circuit breakers and check for power at the
outlet.
Ensure that the room temperature is within 60 -
90°F.
If you do not find a problem, record error code
M0PS0000 and report the problem to the
service organization.
The system appears to be stopped and NO
beep was heard from the system unit.
Processor POST failure. Report error code
M0CPU000.
The system appears to be stopped and NO
beep was heard from the system unit. E122,
E123, or E124 is displayed on the operator
panel display.
No good memory could be found. Report error
code M0MEM000.
The system appears to be stopped. A beep was
heard from the system unit.
No good memory could be found. Report error
code M0MEM001.
The diagnostics are loaded and there was NO
beep heard from the system unit during the IPL
sequence.
Record error code M0SPK001.
The system stops with the Diagnostic Operating
Instructions displayed.
Go to “Step 6” on page 156.
The diskette LED is blinking rapidly, or E1EA or
E1EB is displayed on the operator panel.
The flash EPROM data is corrupted. Run the
recovery procedure for the flash EPROM.
Chapter 8. Hardware Problem Determination
153
Содержание Intellistation POWER 9112 265
Страница 1: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Страница 2: ......
Страница 3: ...Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00 IBM...
Страница 11: ...Sample File modem_f cfg 189 Sample File modem_f0 cfg 192 Sample File modem_f1 cfg 195 Index 199 Contents ix...
Страница 12: ...x User s Guide...
Страница 16: ...xiv User s Guide...
Страница 18: ...xvi User s Guide...
Страница 26: ...6 User s Guide...
Страница 160: ...140 User s Guide...
Страница 164: ...144 User s Guide...
Страница 178: ...158 User s Guide...
Страница 182: ...162 User s Guide...
Страница 192: ...172 User s Guide...
Страница 211: ...responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix F Modem Configurations 191...
Страница 218: ...198 User s Guide...
Страница 222: ...202 User s Guide...
Страница 225: ......
Страница 227: ...Spine information IBM Intellistation POWER 9112 Model 265 User s Guide SA38 0608 00...