Reboot/Restart Policy Setup Menu
Reboot describes bringing the system hardware back up from scratch, for example,
from a system reset or power on. The boot process ends when control passes to the
operating system process.
Restart describes activating the operating system after the system hardware
reinitialized. Restart must follow a successful reboot.
à
ð
Reboot/Restart Policy Setup Menu
1. Number of reboot attempts:
Currently 3
2. Use OS-Defined restart policy?
Currently Yes
3. Enable supplemental restart policy?
Currently No
4. Call-Out before restart:
Currently Disabled
98. Return to Previous Menu
á
ñ
Number of reboot attempts if the server fails to successfully complete the boot
process, it attempts to reboot the number of times specified. Entry values equal
to or greater than 0 are valid. Only successive failed reboots attempts count, not
reboots that occur after a restart attempt. At restart, the counter is set to 0.
Use OS-Defined restart policy lets the Service Processor react or not react the
same as the operating system to major system faults, by reading the setting of
the operating system parameter Automatically Restart/Reboot After a System
Crash. This parameter may, or may not be defined depending on the operating
system or its version/level. If the operating system automatic restart setting is
defined, then it may be set to respond to a major fault by restarting or by not
restarting. See your operating system documentation for details on setting up
operating systems automatic restarts. The default value is YES.
Enable supplemental restart policy - The default setting is NO. If set to YES,
the Service Processor restarts the system when the system loses control as
detected by the Service Processor surveillance, and either:
1. The Use OS-Defined restart policy is set to NO
OR
Chapter 4. Service Processor Menus
4-23
Содержание F50 RS/6000 7025
Страница 1: ...IBM RS 6000 7025 F50 Series IBM User s Guide SA38 0540 01...
Страница 16: ...xvi IBM RS 6000 7025 F50 Series User s Guide...
Страница 18: ...xviii IBM RS 6000 7025 F50 Series User s Guide...
Страница 42: ...2 16 IBM RS 6000 7025 F50 Series User s Guide...
Страница 108: ...3 40 IBM RS 6000 7025 F50 Series User s Guide...
Страница 179: ...d Carefully pull the adapter out of the system Chapter 5 Installing Options 5 35...
Страница 214: ...10 Connect the connector from the EPOW cable to backplane D as shown 5 70 IBM RS 6000 7025 F50 Series User s Guide...
Страница 216: ...c Connect the other end of the power cable to the power supply 5 72 IBM RS 6000 7025 F50 Series User s Guide...
Страница 221: ...Chapter 5 Installing Options 5 77...
Страница 246: ...5 102 IBM RS 6000 7025 F50 Series User s Guide...
Страница 270: ...6 24 IBM RS 6000 7025 F50 Series User s Guide...
Страница 296: ...7 26 IBM RS 6000 7025 F50 Series User s Guide...
Страница 322: ...B 4 IBM RS 6000 7025 F50 Series User s Guide...
Страница 326: ...C 4 IBM RS 6000 7025 F50 Series User s Guide...
Страница 341: ...expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations D 15...
Страница 348: ...D 22 IBM RS 6000 7025 F50 Series User s Guide...
Страница 352: ...E 4 IBM RS 6000 7025 F50 Series User s Guide...
Страница 359: ...Index X 7...
Страница 360: ...X 8 IBM RS 6000 7025 F50 Series User s Guide...
Страница 362: ...X 10 IBM RS 6000 7025 F50 Series User s Guide...
Страница 363: ......