CAUTION:
The
power
control
button
on
the
device
and
the
power
switch
on
the
power
supply
do
not
turn
off
the
electrical
current
supplied
to
the
device.
The
device
also
might
have
more
than
one
power
cord.
To
remove
all
electrical
current
from
the
device,
ensure
that
all
power
cords
are
disconnected
from
the
power
source.
1
2
The
expansion
unit
is
designed
to
run
continuously,
24
hours
a
day.
Turn
off
the
power
only
when
at
least
one
of
the
following
is
true:
v
Instructions
in
a
hardware
or
software
procedure
require
you
to
turn
off
the
power.
v
A
service
technician
tells
you
to
turn
off
the
power.
v
A
power
outage
or
emergency
situation
occurs.
See
“Turning
off
the
expansion
unit
in
an
emergency.”
Complete
the
following
steps
to
turn
off
the
expansion
unit:
1.
Close
all
active
operating
system
windows
and
programs.
2.
Power
down
the
server
attached
to
the
expansion
unit.
3.
Make
sure
that
all
amber
status
and
fault
LEDs
are
off.
If
any
status
or
fault
LEDs
are
lit
(on
hard
disk
drives,
power
supplies,
or
ESMs),
identify
or
correct
the
problem
before
you
turn
off
the
power.
For
more
information,
see
Chapter
5,
“Symptom-to-FRU
index,”
on
page
31.
4.
Turn
off
both
power
supplies.
Turning
off
the
expansion
unit
in
an
emergency
Attention:
Emergency
situations
might
include
fire,
flood,
extreme
weather
conditions,
or
other
hazardous
circumstances.
If
a
power
outage
or
emergency
situation
occurs,
always
turn
off
all
power
switches
on
all
computing
equipment.
This
will
help
safeguard
your
equipment
from
potential
damage
due
to
electrical
surges
when
power
is
restored.
If
the
expansion
unit
loses
power
unexpectedly,
it
might
be
due
to
a
hardware
failure
in
the
power
system
or
midplane,
see
Chapter
5,
“Symptom-to-FRU
index,”
on
page
31.
Complete
the
following
steps
to
turn
off
the
expansion
unit
during
an
emergency
situation:
1.
Close
all
active
operating
system
windows
and
programs.
2.
Power
down
the
server
attached
to
the
expansion
unit.
3.
If
you
have
time,
stop
all
activity
and
check
the
LEDs
(front
and
back).
Make
note
of
any
status
or
fault
LEDs
that
are
lit
so
that
you
can
correct
the
problem
when
you
turn
on
the
power
again.
4.
Turn
off
all
expansion
unit
power
supplies;
then,
unplug
the
power
cables
from
the
expansion
unit.
Turning
on
the
expansion
unit
after
an
emergency
Complete
the
following
steps
to
restart
the
expansion
unit
if
you
turned
off
the
power
supplies
during
an
emergency
shutdown,
or
if
a
power
failure
or
a
power
outage
occurred:
12
IBM
EXP400
Storage
Expansion
Unit
Type
1733:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Содержание EXP400 Type 1733
Страница 2: ......
Страница 22: ...14 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 38: ...30 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 58: ...50 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 59: ...Laser Klass 1 Appendix B Related service information 51...
Страница 60: ...52 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 61: ...Appendix B Related service information 53...
Страница 62: ...54 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 63: ...Luokan 1 Laserlaite Important Appendix B Related service information 55...
Страница 77: ...Appendix B Related service information 69...
Страница 78: ...70 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 79: ...Appendix B Related service information 71...
Страница 80: ...72 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 86: ...78 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 94: ...86 IBM EXP400 Storage Expansion Unit Type 1733 Hardware Maintenance Manual and Troubleshooting Guide...
Страница 97: ......
Страница 98: ...Part Number 90P3548 1P P N 90P3548...