Note
If you cannot find the problem using this
Symptom-to-FRU Index, test the entire system. See
the server documentation for more detailed information
on testing and diagnostic tools.
Problem Indicator
FRU/Action
Hard disk drive not visible in
RAID management
software.
1.
Hard Disk Drive
2. Midplane Board
Amber temperatire LED
onble in RAID management
software.
(ESM Board)
1.
Check for fan fault
LED
2. Unit is overheating.
check temperature.
3. ESM Board
Amber conflict LED on.
(ESM Board)
1.
Tray numbers of ESM
boards within a
single Netfinity FAStT
EXP500 do not
match.
GBIC bypass LED.
Note:
It is normal for the
LED to be on when
no GBIC or cable is
installed.
1.
Check ESM fault
LED.
2. GBIC does not detect
an incoming signal.
a. FC Cable
b. GBIC or other end
on the FC cable.
c. GBIC adjacent to
amber LEDC
cable.
72
IBM Netfinity EXP15, EXP200, EXP500 HMM
Содержание EXP15
Страница 2: ......
Страница 8: ...vi IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 30: ...Parts Listing 1 2 3 4 5 6 7 8 22 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 65: ...Parts Listing 1 2 3 4 5 6 7 Netfinity EXP200 Type 3530 57...
Страница 68: ...60 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 116: ...Parts Listing 1 2 3 4 5 6 7 108 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 124: ...116 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 125: ...Notice n 1 Related Service Information 117...
Страница 132: ...124 IBM Netfinity EXP15 EXP200 EXP500 HMM...
Страница 145: ......
Страница 146: ...IBM Part Number 09N1393 Printed in U S A S1 L 9839 1...